Allen-Bradley 1379-NC360 360A Non-Reversing DC Armature Contactor Kit
Price range: $10,730.34 through $14,164.05
The Allen-Bradley 1379-NC360 is a 360 A non-reversing, electromagnetically held DC contactor kit rated for 500V DC maximum with a 115V AC coil, used to switch DC motor armature current. It is built for the Allen-Bradley 1370 DC Drive Systems. Key ratings: 360A, 500V DC Max, 900A DC Make Current at 550V DC, 115V AC 50/60 Hz Coil, Auxiliary 10A AC Continuous. TCI offers the 1379-NC360 in Used condition, ready to replace a failed unit or expand an existing system.
Description
- Part Number: 1379-NC360
- Manufacturer: Allen-Bradley
- Type: Non-Reversing DC Contactor Kit
- Series: 1379
- Application: DC Motor Armature Switching
- Size // Rating: 360A, 500V DC Max, 900A DC Make Current at 550V DC, 115V AC 50/60 Hz Coil, Auxiliary 10A AC Continuous
- Connection Type: Top-Mounted Power Connections / Vertical Mounting
- Compatibility: Allen-Bradley 1370 DC Drive Systems
TCI is not an authorized Allen-Bradley distributor.
Warranty Coverage
This product is backed by a TCI Supply 1 year Warranty.
Industrial Repair Services
Need your existing hardware restored? We offer professional diagnostic, refurbishment, and repair services for 1379-NC360. Contact our team for a quote.
Request Repair QuoteRequest a Quote
"*" indicates required fields
Description
The Allen-Bradley 1379-NC360 is a 360 A non-reversing, electromagnetically held DC contactor kit rated for 500V DC maximum with a 115V AC coil, used to switch DC motor armature current. Contactors switch power to motors and other loads under the command of a control circuit. The 1379-NC360 belongs to the Allen-Bradley 1379 line and is designed for the Allen-Bradley 1370 DC Drive Systems. It is typically used for DC motor armature switching.
Key ratings for the 1379-NC360: 360A, 500V DC Max, 900A DC Make Current at 550V DC, 115V AC 50/60 Hz Coil, Auxiliary 10A AC Continuous. It connects through top-mounted power connections / vertical mounting. Because it matches the original catalog number, it can be installed as a direct replacement in existing 1379 equipment, or added to expand a system. TCI currently stocks the 1379-NC360 in Used condition. Select the condition above to see its price, or contact TCI for help confirming the right part for your application.
Frequently Asked Questions
What does the 1379-NC360 do in a drive system?
It switches armature current from a DC drive module to the DC motor and can disconnect the motor armature during a power failure or stop.
What coil voltage does the 1379-NC360 use?
The coil and auxiliary contact are rated 115V AC at 50/60 Hz. The coil picks up at up to 75% and drops out at up to 55% of nominal voltage.
What is included in the 1379-NC360 kit?
The kit includes the 360 A contactor, a surge suppressor and instructions.
What contact construction does the 1379-NC360 use?
It has double-break silver cadmium oxide contacts and a magnet with a permanent air gap. Its breakdown voltage is 2,100 V RMS.
What operating temperature and mounting does the 1379-NC360 require?
It operates from 0 to 65 degrees C (32 to 149 degrees F) and is mounted vertically.