Top 10 Signs Your VFD Is About to Fail (And What You Can Do About It)


Variable Frequency Drives (VFDs) are the workhorses of industrial automation—controlling motor speed, improving efficiency, and reducing wear on mechanical systems. But like any electrical component, they don’t last forever. Recognizing early warning signs can save your operation from costly downtime, emergency replacements, and safety hazards. Below are the top 10 signs your VFD might be on its way out—and what you can do about each one before it’s too late.

First things first – Contact TCI Supply for a quote on a new drive for your facility.

1. Intermittent Tripping or Nuisance Faults

If your VFD keeps shutting down for no clear reason, it’s often a sign of a deeper issue: failing internal components, loose wiring, or power quality problems.

What to do:
Check for loose connections, grounding issues, or external noise interference. Review the fault log—especially if you’re using a PowerFlex drive with built-in diagnostics.


2. Overheating or Thermal Trips

A VFD that runs hot or throws thermal faults may have failing fans, clogged filters, or deteriorating internal capacitors.

What to do:
Inspect and clean cooling fans and filters. Use an infrared thermometer or thermal camera to check heat sinks. Replace units showing capacitor bulging or discoloration.


3. Loud or Unusual Noises

Clicking, whining, or electrical buzzing sounds can indicate worn bearings in the cooling fan, loose coils, or capacitor discharge issues.

What to do:
Turn off power and inspect internal components. Replace fans immediately if noisy—many PowerFlex and Siemens drives have field-replaceable fan kits.


4. Burnt Smell or Visual Signs of Damage

The presence of a burnt odor or visible damage (scorch marks, bulging capacitors, melted terminals) means your drive is in immediate jeopardy.

What to do:
Power down the drive and remove it from service. Attempting to run it could cause motor damage or create a fire hazard.


5. Inconsistent Motor Performance

If your motor surges, stalls, or fails to reach commanded speed, the VFD’s output signal may be distorted or its control logic compromised.

What to do:
Use a multimeter or oscilloscope to test output waveform. Check for signs of IGBT failure or failing current sensors.


6. Display Screen or HMI Issues

Flickering, blank, or unresponsive displays may indicate HMI board issues, memory failure, or power supply problems.

What to do:
Replace the keypad/HMI module if available. If the drive powers the HMI internally, it may be a larger power board failure.


7. High Ripple Voltage or DC Bus Issues

Elevated ripple on the DC bus indicates worn-out capacitors and can accelerate failure of other drive components.

What to do:
Test the DC bus with a meter; ripple should be minimal. Replace or refurbish drives with excessive ripple ASAP.


8. Fault Codes That Don’t Clear

When a drive constantly throws fault codes like “Under Voltage,” “Over Current,” or “Ground Fault”—even after resets—it’s usually not just a wiring issue.

What to do:
Cross-reference codes in the manual (e.g., PowerFlex 525 Fault Code List) and test with a known-good motor to rule out load-side problems.


9. Long Power-Up or Reset Times

If your drive takes longer than normal to boot up, it may be a sign of failing firmware, aging EEPROM chips, or internal logic degradation.

What to do:
Ensure firmware is up to date (if applicable). Consider replacing the drive if performance lags persist despite updates.


10. Age and Harsh Environment

Drives exposed to vibration, dust, heat, or moisture—especially beyond 5-8 years of service—are significantly more prone to failure.

What to do:
Proactively replace older VFDs or stock critical spares. Consider conformal-coated models or IP-rated enclosures for harsh environments.


Frequent Series Issues

Brand Popular VFD Series Frequent User Issues Common Solutions / Fixes
Allen-Bradley PowerFlex 4, 40, 70, 700, 525, 753, 755 Overvoltage faults, fan failures, communication errors (EtherNet/IP), parameter resets Replace cooling fans, update firmware, verify network wiring and grounding, save/restore parameters via HIM
Siemens MICROMASTER 420/430/440, SINAMICS G120, V20 Display errors, IGBT failures, excessive noise, startup parameter confusion Use SINAMICS Startdrive or STARTER software for diagnostics, verify wiring, replace aging IGBTs or faulty keypads
Danfoss VLT 2800, FC 102, FC 202, FC 302 Motor instability, noisy output, heat buildup, control signal loss Install output filters if needed, verify proper motor cabling, clean heatsinks, recalibrate analog inputs
Schneider Electric Altivar 12, Altivar 61, Altivar 312/630 Overcurrent trips, EMI issues, keypad lockouts, environment-induced failure Shield signal cables, isolate control circuits, clean filters, reset or unlock keypad, use IP-rated enclosure in dusty settings
Yaskawa V1000, A1000, GA800, J1000 Parameter overload, torque issues, fan noise, encoder faults Back up and reload parameter sets, replace encoder or fan assemblies, engage torque boost functions for heavy loads
ABB ACS355, ACS550, ACS580, ACS880 Communication drops (Modbus, Profibus), motor stalling, internal fan failure Check fieldbus terminations, review motor tuning/setup, use ABB Drive Composer tool for diagnostics, replace fan module
WEG CFW-08, CFW-11, CFW-500, CFW-700 Trip codes without clear cause, overheating, incorrect PID behavior Ensure correct parameter settings, inspect airflow and environment, use WEG software tools to validate PID loop setup
Toshiba VF-S11, VF-AS1, EQP-S3 Sudden stops, braking issues, inconsistent torque Add dynamic braking resistor, enable torque compensation, check for phase imbalance on input

When to Repair vs. Replace

If your drive is under 5 years old and parts are available, repair may be cost-effective. However, for older models—especially discontinued series like Allen-Bradley PowerFlex 40 or Siemens MICROMASTER 440—replacement is often smarter. Newer drives offer better diagnostics, energy savings, and native network compatibility (like EtherNet/IP or PROFINET).

When in Doubt, Replace It Before It Fails

While some VFD issues are fixable, many point to looming failure that can compromise your entire process. If your PowerFlex 70, 700, or legacy Siemens MICROMASTER is showing multiple symptoms above—it may be time to upgrade.

Why Early Detection Matters

A failed VFD can halt an entire process line, costing thousands per hour in downtime. In industries like food processing, water treatment, or pharmaceuticals, the impact can be even more critical due to safety or regulatory concerns. Proactive identification of failure signs allows time to source replacements, align maintenance schedules, and avoid emergency service calls.

👉 Need a replacement fast? Browse VFDs at TCI Supply – same-day shipping available on most PowerFlex 525, 753, and 755T models.

FAQ: Variable Frequency Drive (VFD) Failures

How Long Should a VFD Last?

If the VFD is overheating or tripping on thermal faults and the cooling fan doesn’t spin (or is unusually loud), it’s likely failed. Many PowerFlex and SINAMICS drives allow you to replace the fan module separately.

How do I know if my VFD fan has failed?

If the VFD is overheating or tripping on thermal faults and the cooling fan doesn’t spin (or is unusually loud), it’s likely failed. Many PowerFlex and SINAMICS drives allow you to replace the fan module separately.

What’s the most common cause of VFD failure?

Heat is the #1 enemy. Excessive temperature—often due to blocked airflow or worn-out fans—can shorten the life of capacitors and IGBT modules dramatically.

Can I test a VFD output with a multimeter?

You can measure general voltage output, but a multimeter won’t capture the PWM waveform or diagnose internal gate or IGBT failures. For deeper testing, use an oscilloscope or a dedicated drive analyzer.

Should I back up my VFD parameters?

Yes. Always store a parameter backup using the drive keypad or PC software (like DriveTools, STARTER, Drive Composer). This makes replacements faster and ensures consistent motor behavior.

Do all drives show the same fault codes?

No—fault codes are manufacturer- and model-specific. Refer to the drive’s manual or quick start guide. For example, PowerFlex 525 “F081” means “Heatsink Overtemp” while Siemens might show “F001” for the same condition.