Your PanelView Standard Is Obsolete, and That’s a Problem
Sourcing Spares and Navigating the Migration to PanelView Plus 7
If you’re searching for a replacement for an Allen-Bradley PanelView Standard terminal, any of the 2711 family, from the small 300 and 550 units up to the 1000 and 1400, you’ve probably already run into the bad news- the entire PanelView Standard line is discontinued. Allen-Bradley moved on to the PanelView Plus platform years ago, and the current generation is the PanelView Plus 7 (the 2711P series).
That leaves most people reading this in one of two situations. Either a terminal has failed on a running line and you need it back in production yesterday, or you’re planning ahead. You know the HMI on a critical machine is living on borrowed time and you want to get in front of it before it strands you during a shutdown. Both are real, and they call for different moves.
Here’s the most important thing to understand before you go any further: moving from a 2711 PanelView Standard to a 2711P PanelView Plus 7 is a migration, not a drop-in replacement. The two are different platforms (different hardware, different software, different communications, and in most cases different panel cutouts). You can’t simply unbolt the old terminal, bolt in the new one, and walk away. The application has to be converted, the wiring and network often have to change, and the panel opening may need to be adapted. We’ll walk through exactly what that involves, with a catalog-number cross-reference table to point you toward the right Plus 7 equivalent for your specific model.
And if you can’t migrate right now, because the line is down and you just need the exact part, we’ll cover that too. Sourcing a working spare to keep you running today, while you plan the migration for a scheduled shutdown, is often the smarter sequence than scrambling to do both at once under pressure.
Table of Contents
The Critical Difference: PanelView Standard vs. PanelView Plus 7
Before you pick a replacement, it helps to understand why these two product lines aren’t interchangeable. The PanelView Standard (2711) and the PanelView Plus 7 (2711P) look like they do the same job, and they do, but underneath they’re built on entirely different foundations.
The biggest difference is the software. PanelView Standard applications were built in PanelBuilder32. The PanelView Plus 7 runs applications created in FactoryTalk View Studio, Machine Edition (often shortened to FactoryTalk View ME). These are not the same program, and a PanelBuilder32 file does not simply open on a Plus 7. Your existing application has to be imported and converted into FactoryTalk View ME, and that conversion is rarely perfect on the first pass. Some objects, tags, and features carry over cleanly; others need to be rebuilt or adjusted by hand.
A few specific things tend to trip people up during that conversion. FactoryTalk View ME doesn’t allow dashes in tag names or semicolons in tag addresses, so any tags using those characters have to be renamed before the import or the objects attached to them will break. The “retain last states on startup” option from PanelBuilder32 has no equivalent in FactoryTalk View ME. Long text strings can get truncated, because FactoryTalk View ME caps strings at 82 characters. None of these are dealbreakers, but they’re the kind of detail that turns a “quick swap” into a frustrating afternoon if you’re not expecting them.
The second major difference is communications. PanelView Standard terminals were built for the networks of their era: Remote I/O, DH-485, DH+, and in some cases ControlNet or DeviceNet. The PanelView Plus 7 is built around Ethernet as its primary network. If your existing terminal talks to the PLC over one of the legacy networks, moving to a Plus 7 may mean adding a bridge or changing how that terminal connects to your controller. This is one of the most commonly overlooked parts of the migration, and it’s worth confirming early.
The third difference is physical. The Plus 7 doesn’t always fit the hole your old terminal came out of. Some Plus 7 models drop into the existing panel cutout directly, but many require an adapter kit, and in certain cases (the small PanelView Standard 300, for example) no Plus 7 terminal fits the original cutout at all, which means the panel opening itself has to be modified. We’ll flag which sizes need adapters in the cross-reference table.
None of this is meant to discourage the migration. The Plus 7 is a far more capable terminal: higher resolution, more memory, Ethernet connectivity, remote access, and features the Standard line never had. The point is simply that you should go in knowing this is a planned project with a few predictable steps, not a like-for-like part swap. Understanding that up front is what separates a smooth migration from a painful one.
PanelView 2711 to 2711P Cross-Reference Tables
This is the section to bookmark. Below are the catalog-number conversions from each PanelView Standard (2711) terminal to its closest PanelView Plus 7 (2711P) equivalent, based on Rockwell Automation’s official migration guide (publication 2711P-AP006).
Two things to keep in mind as you read the tables. First, every conversion has a primary option and often a secondary option. The primary is the closest like-for-like PanelView Plus 7 Standard terminal. The secondary is usually a PanelView Plus 7 Performance terminal, which steps you up to keypad-and-touch input, more memory, multiple controller connections, and Device Level Ring (DLR). If your application is simple and you want the nearest match, look at the primary. If you’re modernizing and want headroom, look at the secondary.
Second, confirm three things before you order: the panel cutout (some Plus 7 units drop in, some need an adapter kit, and the small 300 cutout fits no Plus 7 at all), the communications (your legacy terminal may be Remote I/O, DH-485, DH+, ControlNet, or DeviceNet, while the Plus 7 is Ethernet-first), and the power and coating options. On the Plus 7, conformal coating is available on DC-power touch terminals by adding a “K” to the end of the catalog number, for example 2711P-T7C22D9PK.
If you have your exact legacy part number, send it to us and we’ll confirm the correct Plus 7 replacement and check current availability before you commit.
PanelView Standard 300 and 300 Micro
Note the important constraint here: no PanelView Plus 7 terminal fits the original 300 or 300 Micro panel cutout, so this size always involves modifying the panel opening.
| Legacy 2711 model | Legacy comms | Primary Plus 7 replacement | Secondary (Performance) |
|---|---|---|---|
| 2711-K3A5L1K | RS-232 (DF1) | 2711P-T4W21D8S (4″ touch) | 2711P-B7C22D9P (6.5″ key+touch) |
| 2711-K3A10L1 | DH-485 | 2711P-T4W21D8S | 2711P-B7C22D9P |
| 2711-K3A17L1 | RS-232 (DH-485) | 2711P-T4W21D8S | 2711P-B7C22D9P |
| 2711-K3A2L1 | RS-232 (DH-485) | 2711P-T4W21D8S | 2711P-B7C22D9P |
| 2711-K3A5L1 | DeviceNet / RS-232 | 2711P-T4W21D8S | 2711P-B7C22D9P |
| 2711-M3A18L1 (300 Micro) | RS-232 (DF1) | 2711P-T4W21D8S | 2711P-B7C22D9P |
| 2711-M3A19L1 (300 Micro) | RS-232 (DF1) | 2711P-T4W21D8S | 2711P-B7C22D9P |
PanelView Standard 550
The most common legacy size we see. The keypad (K5A), keypad-and-touch (B5A), and touch (T5A) variants all migrate to the same 6-inch Plus 7 primary, with a 6.5-inch Performance unit as the step-up.
| Legacy 2711 model | Legacy comms | Primary Plus 7 replacement | Secondary (Performance) |
|---|---|---|---|
| 2711-K5A1 / -K5A1L1 | Remote I/O | 2711P-T6C21D8S (6″ touch) | 2711P-B7C22A9P / -B7C22D9P |
| 2711-K5A10 / -K5A10L1 | DeviceNet | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-K5A2 / -K5A2L1 | DH-485 | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-K5A8 / -K5A8L1 | DH+ | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-K5A15 / -K5A15L1 | ControlNet | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-K5A20 / -K5A20L1 | EtherNet/IP | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-B5A1 / -B5A1L1 | Remote I/O | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-B5A10 / -B5A10L1 | DeviceNet | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-B5A8 / -B5A8L1 | DH+ | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-B5A20 / -B5A20L1 | EtherNet/IP | 2711P-T6C21D8S | 2711P-B7C22A9P / -B7C22D9P |
| 2711-T5A1L1 | Remote I/O | 2711P-T6C21D8S | 2711P-T7C22D9P |
| 2711-T5A8L1 | DH+ | 2711P-T6C21D8S | 2711P-T7C22D9P |
| 2711-T5A15L1 | ControlNet | 2711P-T6C21D8S | 2711P-T7C22D9P |
| 2711-T5A20L1 | EtherNet/IP | 2711P-T6C21D8S | 2711P-T7C22D9P |
(Note for the body copy: on the 550 keypad and key+touch units, AC power is only on Series A terminals and DC only on Series B, which determines whether the Performance secondary lands on the -A9P or -D9P variant.)
PanelView Standard 600
The 600 is a 5-inch color unit. Keypad (K6C) and key+touch (B6C) variants take the 6.5″ Performance primary and require adapter kit 2711P-RAAK7 for a drop-in fit. Touch-only (T6C) variants map to the 6″ Standard with no adapter needed.
| Legacy 2711 model | Legacy comms | Primary Plus 7 replacement | Adapter kit |
|---|---|---|---|
| 2711-K6C1 / -B6C1 (and L1) | Remote I/O | 2711P-B7C22D9P (6.5″ key+touch) | 2711P-RAAK7 |
| 2711-K6C8 / -B6C8 (and L1) | DH+ | 2711P-B7C22D9P | 2711P-RAAK7 |
| 2711-K6C10 / -B6C10 (and L1) | DeviceNet | 2711P-B7C22D9P | 2711P-RAAK7 |
| 2711-K6C15 / -B6C15 (and L1) | ControlNet | 2711P-B7C22D9P | 2711P-RAAK7 |
| 2711-K6C20 / -B6C20 (and L1) | EtherNet/IP | 2711P-B7C22D9P | 2711P-RAAK7 |
| 2711-K6C2 / -K6C3 / -K6C5 / -K6C9 | DH-485 / RS-232 | 2711P-B7C22D9P | 2711P-RAAK7 |
| 2711-T6C1L1 | Remote I/O | 2711P-T6C21D8S (6″ touch) | N/A (direct) |
| 2711-T6C8L1 | DH+ | 2711P-T6C21D8S | N/A (direct) |
| 2711-T6C10L1 | DeviceNet | 2711P-T6C21D8S | N/A (direct) |
| 2711-T6C15L1 | ControlNet | 2711P-T6C21D8S | N/A (direct) |
| 2711-T6C20L1 | EtherNet/IP | 2711P-T6C21D8S | N/A (direct) |
PanelView Standard 900
The 900 is a 9-inch color or grayscale unit. Both keypad (K9) and touch (T9) variants migrate to the 10.4″ Performance primary and require an adapter kit for drop-in: 2711P-RAAK10 for keypad, 2711P-RAAT10 for touch.
| Legacy 2711 model | Legacy comms | Primary Plus 7 replacement | Adapter kit |
|---|---|---|---|
| 2711-K9C1 / -K9A1 (and L1) | Remote I/O | 2711P-B10C22D9P (10.4″ key+touch) | 2711P-RAAK10 |
| 2711-K9C8 / -K9A8 (and L1) | DH+ | 2711P-B10C22D9P | 2711P-RAAK10 |
| 2711-K9C10 / -K9A10 (and L1) | DeviceNet | 2711P-B10C22D9P | 2711P-RAAK10 |
| 2711-K9C15 / -K9A15 (and L1) | ControlNet | 2711P-B10C22D9P | 2711P-RAAK10 |
| 2711-K9C20 (and L1) | Ethernet | 2711P-B10C22D9P | 2711P-RAAK10 |
| 2711-K9C3 / -K9C9 / -K9A2 / -K9A3 | DH-485 / RS-232 | 2711P-B10C22D9P | 2711P-RAAK10 |
| 2711-T9C1 / -T9A1 (and L1) | Remote I/O | 2711P-T10C22D9P (10.4″ touch) | 2711P-RAAT10 |
| 2711-T9C8 / -T9A8 (and L1) | DH+ | 2711P-T10C22D9P | 2711P-RAAT10 |
| 2711-T9C10 / -T9A10 (and L1) | DeviceNet | 2711P-T10C22D9P | 2711P-RAAT10 |
| 2711-T9C15 / -T9A15 (and L1) | ControlNet | 2711P-T10C22D9P | 2711P-RAAT10 |
| 2711-T9C20 (and L1) | Ethernet | 2711P-T10C22D9P | 2711P-RAAT10 |
PanelView Standard 1000
The 1000 is a 10-inch color or grayscale unit. Both keypad (K10) and touch (T10) variants migrate to the 12.1″ widescreen Performance primary and require an adapter kit: 2711P-RAAT12K for keypad, 2711P-RAAT12 for touch.
| Legacy 2711 model | Legacy comms | Primary Plus 7 replacement | Adapter kit |
|---|---|---|---|
| 2711-K10C1 / -K10G1 (and L1) | Remote I/O | 2711P-T12W22D9P (12.1″ wide) | 2711P-RAAT12K |
| 2711-K10C8 / -K10G8 (and L1) | DH+ | 2711P-T12W22D9P | 2711P-RAAT12K |
| 2711-K10C10 / -K10G10 (and L1) | DeviceNet | 2711P-T12W22D9P | 2711P-RAAT12K |
| 2711-K10C15 / -K10G15 (and L1) | ControlNet | 2711P-T12W22D9P | 2711P-RAAT12K |
| 2711-K10C20 / -K10G20 (and L1) | Ethernet | 2711P-T12W22D9P | 2711P-RAAT12K |
| 2711-K10C3 / -K10C9 / -K10G3 / -K10G9 | DH-485 / RS-232 | 2711P-T12W22D9P | 2711P-RAAT12K |
| 2711-T10C1 / -T10G1 (and L1) | Remote I/O | 2711P-T12W22D9P (12.1″ touch) | 2711P-RAAT12 |
| 2711-T10C8 / -T10G8 (and L1) | DH+ | 2711P-T12W22D9P | 2711P-RAAT12 |
| 2711-T10C10 / -T10G10 (and L1) | DeviceNet | 2711P-T12W22D9P | 2711P-RAAT12 |
| 2711-T10C15 / -T10G15 (and L1) | ControlNet | 2711P-T12W22D9P | 2711P-RAAT12 |
| 2711-T10C20 / -T10G20 (and L1) | Ethernet | 2711P-T12W22D9P | 2711P-RAAT12 |
PanelView Standard 1400
The 1400 is a 14-inch color unit. Unlike the smaller sizes, Rockwell lists a single replacement option: the 15″ Standard touch terminal, no adapter kit. Note the 1400 keypad versions migrate to a touch terminal, so function-key operation changes (the F17 to F21 keys on the 1400 don’t carry over one-to-one).
| Legacy 2711 model | Legacy comms | Plus 7 replacement | Adapter kit |
|---|---|---|---|
| 2711-T14C1 / -K14C1 | Remote I/O | 2711P-T15C21D8S (15″ touch) | N/A |
| 2711-T14C8 / -K14C8 | DH+ | 2711P-T15C21D8S | N/A |
| 2711-T14C10 / -K14C10 | DeviceNet | 2711P-T15C21D8S | N/A |
| 2711-T14C15 / -K14C15 | ControlNet | 2711P-T15C21D8S | N/A |
| 2711-T14C20 / -K14C20 | Ethernet | 2711P-T15C21D8S | N/A |
| 2711-T14C3 / -T14C9 / -K14C3 / -K14C9 | DH-485 / RS-232 | 2711P-T15C21D8S | N/A |
Bonus: PanelView Enhanced (2711E) terminals
| Legacy 2711E model | Legacy comms | Plus 7 replacement |
|---|---|---|
| 2711E-K10C6 / -K10C15 (1000e keypad) | Remote I/O / ControlNet | 2711P-B15C22A9P (15″ key+touch) |
| 2711E-K12C6 (1200e keypad) | Remote I/O | 2711P-B15C22A9P |
| 2711E-K14C6 / -K14C15 (1400e keypad) | Remote I/O / ControlNet | 2711P-T15C21D8S (15″ touch) |
What the Migration Actually Involves
Once you’ve picked your replacement terminal, four things need attention before you’re back up and running.
Convert the application. Your PanelBuilder32 file won’t open on a Plus 7. You import it into FactoryTalk View Studio (Machine Edition), which converts it. Budget time to clean up afterward: rename any tags containing dashes and replace semicolons in addresses before importing, or those objects break. Expect to adjust screen layouts too, since the Plus 7’s higher resolution means your old screens land in the top-left corner unless you rescale them.
Plan the communications change. PanelView Plus 7 terminals use Ethernet only. If your existing terminal runs Remote I/O, DH-485, DH+, ControlNet, or DeviceNet, you’ll need a gateway to bridge that legacy network, or you’ll move the terminal connection to Ethernet.
Check the cutout and adapter. Some Plus 7 terminals drop into the existing hole; the 600, 900, and 1000 keypad and touch units need a specific adapter kit (listed in the tables above). The small 300 cutout fits no Plus 7 at all and requires panel rework. One caution: those adapter kits are for Plus 7 Performance terminals only, so don’t force a Standard terminal into one.
Confirm power. Plus 7 terminals are DC-powered. If your old terminal ran on AC, add a 24V DC power supply to the bill of materials. It’s a small line item that’s easy to forget and annoying to discover mid-install.
None of this is difficult on its own. The migrations that go badly are the ones where a step gets discovered late, on a Friday, with the line down.
When the Part You Need Is Already Discontinued
Here’s the complication that sends most people to this page in the first place: the PanelView Standard line isn’t just old, it’s discontinued. New stock is scarce, lead times are unpredictable, and the obsolescence often runs deeper than people expect.
It’s common to trace a part forward to its official replacement, only to find that the replacement has also been discontinued. A terminal was superseded years ago, the successor had a normal production run, and now that successor is end-of-life too. Follow the catalog-number trail far enough and you can hit two or three dead ends before you reach anything currently in production. By that point you’re not really shopping, you’re hunting.
This is exactly where a sourcing partner earns its keep. The open market for obsolete and refurbished PanelView terminals is wide, and prices swing dramatically: some sellers ask many times what a unit is reasonably worth, betting that a buyer with a down line will pay anything. Knowing what’s genuinely available, what condition it’s in, and what fair pricing looks like is the difference between a quick fix and an expensive scramble.
At TCI Supply, sourcing discontinued Allen-Bradley controls is our core business. We carry, locate, and verify obsolete and hard-to-find 2711 and 2711P terminals, so whether you need the exact legacy part to keep a line running or the correct Plus 7 equivalent to modernize, you have one place to ask instead of a dozen.
Repair, Replace, or Migrate: Making the Call
When a PanelView Standard terminal fails, you have three moves, and the right one depends on how much time you have.
Source a spare and keep running. If the line is down and you need it back now, the fastest path is a working replacement of the exact part, refurbished or new-old-stock. This buys you time and changes nothing else in the panel. It’s the right call in an emergency, and it lets you plan the upgrade on your own schedule instead of under pressure.
Repair what you have. If the unit is hard to find and your application is stable, repairing the existing terminal can be the most cost-effective option. It keeps your known-good configuration in place.
Migrate to PanelView Plus 7. When you have the runway, usually a planned shutdown, migrating to a current Plus 7 terminal is the long-term answer. You get a supported platform, Ethernet connectivity, and years of availability ahead of you instead of behind.
The smartest sequence is often a combination: source a spare to get running today, then migrate to the Plus 7 at your next scheduled downtime. That way the breakdown never dictates the timeline.
Whichever path fits, the starting point is the same. Send us your PanelView part number and we’ll confirm what’s available, identify the correct Plus 7 equivalent, and get you a quote. Whether you need the exact legacy terminal to keep a line running or help speccing the migration, contact TCI Supply or call us at 1-800-755-2883. TCI Supply is mnot an authorized Allen-Bradley distributor.



