Yaskawa Drive Migration Cross Reference: V7 → V1000 → GA500

Yaskawa Logo

Yaskawa’s micro-drive line has turned over twice: the VS606 V7 gave way to the V1000, and the V1000 to the current GA500. Yaskawa published an official transition guide for each hop — but a plant holding a failed V7 today needs both hops at once, and that two-generation cross is what this page assembles.

The tables run three columns — V7 model → V1000 model → GA500 model — by voltage class and capacity, drawn directly from Yaskawa’s two transition guides. Read the notes column with the same seriousness as the model column: each generation changed dimensions (mounting-hole patterns differ on several frames), terminal layout (control terminal designations moved between generations, so a wiring translation is part of the job, not an afterthought), and braking and network options (option-card ecosystems don’t carry across; the GA500’s equivalents are listed where they exist).

One honest caveat, stated plainly: Yaskawa never published a direct V7-to-GA500 document. The third column is the composition of two official crosses, which is reliable for model selection but means commissioning details should be verified against the GA500 documentation rather than assumed from V7 habits. Parameter mapping in particular is a two-step translation — our team can walk it with you.

1. Navigating a Two-Generation Drive Migration

This guide performs a “chained cross” from the legacy VS606 V7 through the intermediate V1000 directly to the modern GA500. Because the hardware evolved significantly across twenty years, control wiring (e.g., sink/source dip switches and terminal designations) and physical mounting footprints are rarely a direct one-for-one drop-in. Treat this cross-reference as the foundation for the replacement BOM, and consult our application engineers to map your specific I/O and parameter sets.

2. 200V Single-Phase: V7 to V1000 to GA500 Cross Reference

Legacy V7 Model V1000 Model Current GA500 Model Motor Output (ND/HD)
CIMR-V7AMB0P1 CIMR-VUBA0001FAA GA50B001F 1/8 HP
CIMR-V7AMB0P2 CIMR-VUBA0002FAA GA50B002F 1/4 HP
CIMR-V7AMB0P4 CIMR-VUBA0003FAA GA50B004F 1/2 HP
CIMR-V7AMB0P7 CIMR-VUBA0006FAA GA50B006F 1 HP
CIMR-V7AMB1P5 CIMR-VUBA0010FAA GA50B010F 2 HP
CIMR-V7AMB2P2 CIMR-VUBA0012FAA GA50B012F 3 HP

3. 200V Three-Phase: V7 to V1000 to GA500 Cross Reference

Legacy V7 Model V1000 Model Current GA500 Model Motor Output (ND/HD)
CIMR-V7AM20P1 CIMR-VU2A0001FAA GA502001A 1/8 HP
CIMR-V7AM20P2 CIMR-VU2A0002FAA GA502002A 1/4 HP
CIMR-V7AM20P4 CIMR-VU2A0004FAA GA502004A 1/2 HP
CIMR-V7AM20P7 CIMR-VU2A0006FAA GA502006A 1 HP
CIMR-V7AM21P5 CIMR-VU2A0010FAA GA502010A 2 HP
CIMR-V7AM22P2 CIMR-VU2A0012FAA GA502012A 3 HP
CIMR-V7AM23P7 CIMR-VU2A0021FAA GA502021A 5 HP
CIMR-V7AM25P5 CIMR-VU2A0030FAA GA502030A 7.5 HP
CIMR-V7AM27P5 CIMR-VU2A0040FAA GA502042A 10 HP

4. 400V Three-Phase: V7 to V1000 to GA500 Cross Reference

Legacy V7 Model V1000 Model Current GA500 Model Motor Output (ND/HD)
CIMR-V7AM40P2 CIMR-VU4A0001FAA GA504001A 1/4 HP
CIMR-V7AM40P4 CIMR-VU4A0002FAA GA504002A 1/2 HP
CIMR-V7AM40P7 CIMR-VU4A0004FAA GA504004A 1 HP
CIMR-V7AM41P5 CIMR-VU4A0005FAA GA504005A 2 HP
CIMR-V7AM42P2 CIMR-VU4A0007FAA GA504007A 3 HP
CIMR-V7AM43P7 CIMR-VU4A0011FAA GA504011A 5 HP
CIMR-V7AM44P0 CIMR-VU4A0011FAA GA504011A 5.5 HP
CIMR-V7AM45P5 CIMR-VU4A0018FAA GA504018A 7.5 HP
CIMR-V7AM47P5 CIMR-VU4A0023FAA GA504023A 10 HP

5. Dimension, Terminal & Option Considerations

Migration Consideration V7 to V1000 Changes V1000 to GA500 Changes Action Required (Chained Cross)
Physical Dimensions & Mounting V1000 generally narrower and deeper than V7. GA500 mounting holes match V1000 for most frames. Compare original V7 drill pattern directly to GA500 manual. Adapter plates may be required for tight MCCs.
Control Terminal Designations SC changed to SN (Source/Sink logic). Minimal terminal name changes; logic remains similar. Verify NPN/PNP (Sink/Source) jumper settings. V7’s “SC” corresponds to the GA500’s “SN” for common connections.
Communication & Option Cards V7 networks moved to V1000 SI- series cards. GA500 introduces JOHB- series communication cards. Legacy V7 comms cannot be reused. Must specify new GA500 network card (e.g., EtherNet/IP, Modbus TCP) at time of order.
Parameter Structure n-Parameters translated to letter-group (e.g., A1-01). Retains letter-group structure with expanded functionality. Parameter sets must be completely rebuilt. DriveWizard Industrial software is highly recommended for translation.

6. Source Reference Documents & Resources

Source Reference Documents (PDF):

Related Resources & Categories:

7. Source Your Yaskawa Drives From TCI Supply

We ship these products worldwide! Delivery is normally stock. Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Cross-references are provided as a selection aid. Two-generation drive migrations require complete parameter re-commissioning, wiring audits, and footprint verification. Always consult a TCI Application Engineer and official documentation before committing to a legacy drive upgrade.

Get A Quote

Fill in the form below, or call us now at 1-800-755-2883

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Full Product Catalog

See our comprehensive product catalog!