Siemens 1010NR-T2KGS-S2 Flow Meter Controller

$3,930.00

The Siemens 1010NR-T2KGS-S2 is a SITRANS FUS1010 ultrasonic flow meter transmitter that measures liquid flow using WideBeam transit-time technology. The unit is hazardous-area rated and supplied in a Type 4X enclosure for outdoor or washdown service.

SKU: 1010NR-T2KGS-S2 Category: Brand:

Description

  • Clamp On Sensors: Install without cutting pipe or stopping flow.
  • Hazardous Area Rated: Wire directly into Division 1 zones.
  • Wide Voltage Range: Works on most global mains supplies.
  • Type 4X Enclosure: Mount outdoors without extra weatherproofing.
  • Multi-Agency Approvals: Deploys across global markets without requalification.

Technical Specifications

Manufacturer Siemens
Part Number 1010NR-T2KGS-S2
Type Controller
Series 1010 Series
Power Supply 90V – 240V, 50-60 Hz
Enclosure Type 4X
Approvals CSA, FM Approved, CE

Request a Quote

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Description

The Siemens 1010NR-T2KGS-S2 is a SITRANS FUS1010 ultrasonic flow meter transmitter designed for liquid flow measurement using WideBeam transit-time technology. Its clamp-on transducers mount on the outside of the pipe, so the meter measures flow without contacting the process fluid or requiring a process shutdown to install.

The transmitter runs on 90 to 240 VAC at 50 or 60 Hz and is housed in a Type 4X enclosure. It is approved as AEx [ia] IIC associated equipment with intrinsically safe connections for Class I Division 1 and Class II Division 1 locations. Certifications include CSA, FM, CE, and C-tick.

Frequently Asked Questions

Do the sensors contact the process medium, and do I need to cut into the pipe to install it?

No. The sensors mount on the outside of the pipe and make no contact with the medium, so the line stays sealed. Installation and commissioning are straightforward, including on large pipe sizes.

Can the FUS1010 be installed in hazardous or classified locations?

Yes. It is rated Class I, Zone 2, AEx nC [ia] IIC T5, with intrinsically safe connections for Class I, Division 1 and suitability for Class I, Division 2 and Class II, Division 2 areas. Install per Siemens drawing 1010-304, keep the cover closed when power is applied, and bond the conduit hubs together on installation.

Is the enclosure suitable for wet, outdoor, or washdown environments?

Yes. The Type 4X enclosure is built for wet and corrosive conditions in indoor and outdoor installations. The unit also carries CSA, FM Approved, and CE marks for regulated applications.