Allen-Bradley 100-D180ZJ22L Bulletin 100-D 180A 3-Pole DC-Operated IEC Contactor
$1,843.26
The Allen-Bradley 100-D180ZJ22L is a Bulletin 100-D 3-pole DC-operated IEC contactor rated 180 A with a 24V DC conventional coil, built-in surge suppression, and IP20 protection. It is built for the Allen-Bradley Bulletin 100-D Contactor Line. Key ratings: 180A, 3 Poles, 24V DC Conventional Coil, IP20. TCI offers the 100-D180ZJ22L in Used condition, ready to replace a failed unit or expand an existing system.
Description
- Part Number: 100-D180ZJ22L
- Manufacturer: Allen-Bradley
- Type: 3-Pole DC-Operated IEC Contactor
- Series: Bulletin 100-D
- Application: Motor Starting & Load Switching
- Size // Rating: 180A, 3 Poles, 24V DC Conventional Coil, IP20
- Connection Type: Bolt-Type Terminals / Panel Mount
- Compatibility: Allen-Bradley Bulletin 100-D Contactor Line
TCI is not an authorized Allen-Bradley distributor.
Technical Specifications
| Condition | Used |
|---|
Request a Quote
"*" indicates required fields
Description
The Allen-Bradley 100-D180ZJ22L is a Bulletin 100-D 3-pole DC-operated IEC contactor rated 180 A with a 24V DC conventional coil, built-in surge suppression, and IP20 protection. Contactors switch power to motors and other loads under the command of a control circuit. The 100-D180ZJ22L is designed for the Allen-Bradley Bulletin 100-D Contactor Line. It is typically used for motor starting & load switching.
Key ratings for the 100-D180ZJ22L: 180A, 3 Poles, 24V DC Conventional Coil, IP20. It connects through bolt-type terminals / panel mount. Because it matches the original catalog number, it can be installed as a direct replacement in existing Bulletin 100-D equipment, or added to expand a system. TCI currently stocks the 100-D180ZJ22L in Used condition. Select the condition above to see its price, or contact TCI for help confirming the right part for your application.
Frequently Asked Questions
What comes factory-assembled on the 100-D180ZJ22L?
The description lists factory-supplied terminal lugs, 2 normally open auxiliary contacts, 1 normally closed auxiliary contact, 1 late-break normally closed auxiliary contact, a surge suppression circuit, and a 24 V DC conventional coil.
What is its operating temperature range?
It has a standard rated operating temperature range of -25 to 60 C.
How is the main power circuit connected?
It uses a bolt-in type connection with flat-ended line-side terminals and is designed for panel installation.
Does it have a PLC interface?
No, the 24 V DC conventional coil version does not include a PLC interface.