ABB A75-30-11 Contactor

$420.00

The ABB A75-30-11 is a 3-pole, 75 Amp contactor with a 110-120V AC coil for motor control applications.

1 in stock

SKU: A75-30-11 Category: Brand:

Description

  • A 3-pole IEC-rated industrial contactor.
  • Rated for 75 Amps (AC-3).
  • Features a 110-120V 50/60Hz control coil.
  • Includes a 1NO/1NC auxiliary contact block.

Technical Specifications

Part Number A75-30-11
Manufacturer ABB
Type IEC Contactor
Application Motor Control, Power Switching
Series A-Line
Compatibility Motor loads
Size / Rating 75A, 110-120V Coil
Connection Type Screw Terminals

Request a Quote

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Frequently Asked Questions

What are the main applications for the A75-30-11?

This contactor is primarily designed for controlling 3-phase electric motors. However, its robust design also makes it suitable for other applications, including:
- Motor starting (its primary use, rated AC-3)
- Isolation
- Capacitor switching (for power factor correction)
- Controlling non-inductive or slightly inductive loads (like resistance furnaces or lighting, rated AC-1)

What common accessories can be added to the A75-30-11?

A key feature of the A-line series is its modularity. You can add several accessories, including:
- Additional Auxiliary Contacts: These can be mounted on the front (e.g., CA5 series) or the side (e.g., CAL5 series) to add more control contacts (e.g., for signaling and interlocks).
- Mechanical Interlocks: Used to connect two contactors side-by-side to create a reversing starter, ensuring that only one contactor can be engaged at a time.
- Timers: Pneumatic or electronic timers can be attached to create time-delay functions.
- Replacement Contacts: A 3-pole main contact kit (ZL75) is available to service the contactor and extend its life.

What are the key maintenance and safety tips for this contactor?

Proper maintenance ensures safety and longevity.
- SAFETY FIRST: Always de-energize all power and control circuits and lock out the system before performing any inspection or maintenance.
- Check Connections: The most common failure point is a loose connection. Periodically check that all power and control terminals are tightened to their specified torque. Overheating or discoloration at a terminal is a clear sign of a loose wire.
- Keep it Clean: Use a vacuum or dry, low-pressure air to clean any dust or debris from the contactor and its arc chutes.
Inspect, Don't File: Visually inspect the main contacts for excessive pitting or wear. Do not file or sand the contacts. A discolored or slightly pitted surface is normal. If the silver contact material is gone, the contacts should be replaced.