GE to ABB Cross Reference (Contactors, Starters & Breakers)

ABB Logo

GE’s industrial control and distribution business — the contactors, starters, and molded case breakers on nameplates everywhere — was acquired by ABB in 2018. Some lines continued under ABB with the same catalog numbers; others were formally transitioned to ABB families with published crosses. Knowing which situation your part is in is half the battle, and this page sorts it.

Continued lines: the CR305/CR306/CR309 NEMA contactors and starters remain in production under ABB — your GE CR305 catalog number is the current ABB catalog number, and renewal coils, contact kits, and auxiliary blocks carry forward. Transitioned lines with official crosses: GE definite-purpose contactors have a published ABB cross-reference (transcribed below), and GE’s Spectra™ and Q-Line enclosed breakers transition to ABB’s FORMULA A2 and Tmax XT families — frame by frame, with the rating-plug caveats ABB flags where a cross lands in a lower frame capacity. Legacy layers: older GE lighting contactors (CR160MC) and Joslyn Clark-era crosses are mapped in their own tables for plants maintaining pre-1990s gear.

The tables below are organized by product family with the ABB source document cited on each — check the notes column, because a handful of breaker crosses change accessories or footprint.

We stock GE-legacy and current ABB control across all of these families, plus the obsolete originals when matching existing gear matters more than modernizing. Part number and a nameplate photo gets you a verified cross and a quote, usually same day.

1. The GE to ABB Industrial Transition

When ABB acquired GE Industrial Solutions, they implemented a multi-tiered migration strategy. Certain core lines—most notably the heavy-duty NEMA motor control sector—were rebranded to ABB but kept their exact part numbering structures and physical footprints, allowing for perfect backwards compatibility. However, breaker frames and Definite Purpose (HVAC-style) contactors were phased out and replaced by ABB’s globally standardized lines (Tmax XT and DP series). Navigating this requires checking whether your part number is a “continued line” or a “transitioned line.”

2. CR305 / CR306 NEMA Control (Continued Lines)

The classic GE NEMA motor control line was adopted by ABB in its entirety. You do not need to cross-reference these part numbers to a new format; the legacy GE catalog number is the current ABB catalog number.

Legacy GE Product Line Product Type Current ABB Status Notes
CR305 Series NEMA Contactors ABB CR305 Series Continued line. Coils, contact kits, and footprints match identically.
CR306 Series NEMA Starters ABB CR306 Series Continued line. Overload heater tables remain unchanged.
CR309 Series Reversing Starters ABB CR309 Series Continued line. Mechanical interlocks are backward compatible.

3. GE Definite Purpose Contactors to ABB Cross Reference

Legacy GE DP Series Amp Range ABB Replacement Series Reference & Notes (LCM 5/15/19)
CR453A / CR553A 20A – 40A ABB DP Series (e.g., DP30C…) Verify coil voltage matching (24V, 120V, 240V). Multi-mounting base provided on most ABB models.
CR453B / CR553B 50A – 90A ABB DP Series (e.g., DP50C…) Lug size and wire capacity must be verified if replacing older 90A 3-pole configurations.

4. Spectra & Q-Line Breakers to FORMULA A2 / Tmax XT

The GE Spectra and Q-Line breakers were officially phased out. Replacements using ABB FORMULA and Tmax XT breakers often require specialized panelboard mounting kits or rating plug adjustments.

Legacy GE Frame ABB Replacement Frame Mounting / Trip Unit Notes ABB Guide Ref
Q-Line (THQB, THQC) FORMULA A2 Mounting footprints vary. Often requires a retrofit kit for panelboard installation. 1SXU930001G0201
Spectra SE150 (SEHA, SELA) Tmax XT2 / XT4 Tmax XT utilizes advanced Ekip trip units or standard thermal-magnetic. Rating plugs must match exact load requirements. 1SXU930001G0201
Spectra SF250 (SFHA, SFLA) Tmax XT4 Direct swap requires specific panelboard hardware adapter kits. 1SXU930001G0201
Spectra SG600 (SGHA, SGLA) Tmax XT5 Higher short-circuit current ratings (SCCR) available on XT5. Verify busbar clearances. 1SXU930001G0201
Spectra SK1200 (SKHA, SKLA) Tmax XT7 Requires careful specification of Ekip Dip or Ekip Touch trip unit configurations. 1SXU930001G0201

5. Legacy CR160MC Lighting & Joslyn Clark Cross Reference

Legacy System Legacy Model GE / ABB Replacement Notes
GE Lighting Contactors CR160MC Series CR460 Series Verify pole count (configurable up to 12 poles) and mechanically held vs. electrically held operation.
Joslyn Clark Contactors CV Series (e.g., CV2, CV3) ABB/GE CR305 / CR306 Cross published via legacy Catalog 057102200. Match exact NEMA size and coil voltage.

6. Source Reference Documents & Resources

Source Reference Documents:

Related Resources & Categories:

7. Source Your Hardware From TCI Supply

We ship these products worldwide! Delivery is normally stock. Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Cross-references are provided as a selection aid. Breaker retrofits require strict adherence to panelboard sizing, continuous current constraints, and interrupting capacities (AIC). Always consult a TCI Application Engineer and official documentation before committing to a legacy breaker upgrade.