Device To Be Replaced Current
Replacement
7800 Series
Replace-
ment  
Wiring Number Number Comments
R177A RA890F 1 RM7890A1015 power—1,2 limit—1-5 motor—3 ignition—4 controller—R,W,B detector—F,G Remove Series 10 Controller and rewire.
Same as RA890F except does not have “proof of flame” terminal (terminal 5 on RA890E,F).
Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R180A RA890F 1 RM7890A1015 power—1,2 jumper—1-3
limit, main valve—4 controller—R,W,B detector—F,G
Continuous pilot applications only. Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA 890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R180B RA890F 1 RM7890A1015 power -1,2
limit, main valve—5 motor, pilot valve—3 ignition—4 controller—R,W,B detector—F,G
Functionality same as RA890F.
Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R187A RA890F 1 RM7890A10105 power—1,2 limit—1-5 motor—3 ignition—4 controller—R,W,B detector—F,G Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R190B, RA190B RA890F 1 RM7890A1015 See 180B Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R190C R4138C,D RA890H 4 RM7838A,B RM7890B1014 See Modernization Wiring Information section. Used in W124 and ID051 panels.
See Modernization Wiring Information section.
R887A RA890F 1 RM7890A1015 power—1,2 limit—1-5 motor—3 ignition—4 controller—T,T detector—F,G Rewire.
Requires Q270A Subbase with RA89OF.
Requires Q7800f1004 Subbase with RM7890A1015.
R890B, RA890B RA890F 1 RM7890A1015 power—1,2 limit—1
motor,pilot valve—3 ignition—4
main valve—5 controller—6 jumper—T,T detector—F,G
Requires Q7800F1004 Subbase with RM7890A1015.
R890C, RA890C RA890F 1 RM7890A1015 Same as R890B, RA890B Requires Q7800Fl004 Subbase with RM7890A1015.
RA890XB RA890XC RA890F 1 RM7890A1015 Same as R890B, RA890B Requires Q7800F1004 Subbase with RM7890A1015.
RA890D R4140M 1 RM7840M1017 Same as R890B, RA890B except controller always on terminal 6 and LF switch to T,T Requires Q520A Subbase and R7247A Amplifier with R4140M.
Requires Q7800L1001 Subbase and R7847A1009 or R7847B1007 Amplifier with RM7840M1017.

 

Specifications Current
Rplcmt.
SERIES 7800
Replacement
RA890H,J,K
OS Number to be
Replaced 6        7
Voltage
(50/60)
RA890H1011 208 None None
RA890H1029 240 None None
RA890H1037 100 None None
RA890H1045 220 None None
RA890H1052 120 H1052 RM7890A1015
RA890J1008 120 J1008 None
RA890J1016 120 J1008 None
RA890J1024 208 None None
RA890J1032 240 None None
RA890K1006 120 H1052 RM7890A1015

 

Device To Be Replaced
R4075A1009
Current
Replace-
ment
NONE
SERIES
7800
Replace-
ment
NONE
R4075A1025 NONE NONE
R4075A1033
R4075A1041
NONE
NONE
NONE
NONE
R4075A1058
R4075B1007
R4075B1015
R4075B1023
R4075B1031
R4075B1049
R4075B1056
R4075C1005
R4075C1013
R4075C1021
R4075C1039
R4075D1003
R4075E1000
R4075E1018
NONE R4075C1005 7
R4075C1005 7
R4075C1005 8
R4075C1005 7
R4075C1005 8
R4075C1005
R4075C1005
R4075C1013
R4075C1021
R4075C1039
R4075D1003
R4075E1000
NONE
NONE RM7885A1015 6
RM7885A1015 6
RM7885A1007 13
RM7885A1015 6
RM7885A1007 13
RM7885A1015 6
RM7885A1015 6
NONE NONE NONE
RM7885A1015 6
NONE NONE

 

R4795A1099
R4795A1107
R4795C1004
R4795D1002
R4795D1010
R4795D1028
R4795D1036
R4795D1044
R4795D1051
R4795D1069
R4795A1099
R4795A1107
R4795A1016 2
R4795D1002
R4795A1002
None None None
R4795D1051
R4795D1069
None
None
RM7895A1014
RM7895B1013
RM7895C1012
RM7895D1011
RM7895A1014
RM7895B1013
RM7895C1012
RM7895D1011
RM7895A1014RM7895B1013
RM7895C1012
RM7895D1011
None None None
RM7895A1014RM7895B1013
RM7895C1012
RM7895D1011
None

 

Device to be Replaced R7023A1005    Current       Replacement     R7023B1003 Series 7800
Replacement
RM7823A1016
R7023A1021 R7023B1052 None
R7023A1039 R7023B1011 None
R7023A1047 R7023B1003 5 RM7823A1016
R7023A1054 None None
R7023A1062 R7023B1052 5 None
R7023A1070 R7023B1037 None
R7023B1003 R7023B1003 RM7823A1016
R7023B1011 R7023B1011 None
R7023B1029 None None
R7023B1037 R7023B1037 None
R7023B1045 R7023B1003 5 RM7823A1016
R7023B1052 R7023B1052 None
R7023B1060
R7023C1001
R7023B1052 5
R7023C1001
NoneE RM7823A1016
R7023C1019 R7023C1019 RM7823A1016
R7023C1027 R7023C1027 None
R7023C1035 R7023C1035 None
R7023C1043 R7023C1050 6 None
R7023C1050
R7023C1068
R7023C1050
None
None
RM7823A1016
R7023X1002 None None
R7023X1010
R7023X1028
None
R7023B1052
None
None
R7023X1036 R7023B1052 5 None
R7023X1044 R7023B1052 None
R7023X1051
R7023X1069
R7023X1077
R7023X1085
R7023X1093
R7023B1052 5
R7023B1052 5     7
None
R7023B1052 5     7
R7023C1027
None None None None None