The Honeywell Primary Control Cross Reference Guide serves as a comprehensive resource for professionals seeking to upgrade or replace legacy burner controls with modern Honeywell systems. This guide facilitates the transition from older models to contemporary solutions by providing detailed cross-references and wiring information.
Ordering Guide
Cross-Reference Overview:
The guide systematically matches obsolete or less common controls to current Honeywell models, particularly focusing on the 7800 Series—a microprocessor-based integrated burner control platform suitable for single-burner applications. For example, devices like the R177A, R180A, and R187A are recommended to be replaced with the RA890F model. Further modernization can be achieved by transitioning to the RM7890A1015 from the 7800 Series. This upgrade enhances functionality and reliability in burner management systems.
Wiring and Subbase Requirements:
Upgrading to newer models often necessitates changes in wiring configurations and subbases. The guide specifies that replacing certain models with the RA890F requires the Q270A Subbase, while transitioning to the RM7890A1015 necessitates the Q7800F1004 Subbase. These specifications ensure compatibility and optimal performance of the new controls.Honeyvell Energy
Detailed Replacement Tables:
The document includes extensive tables that detail the specifications of various models, such as operating voltage, frequency, safety switch timing, flame failure response time, and the presence of alarm contacts. For instance, the RA890E series has multiple variants with differing specifications, each mapped to a suitable replacement in the 7800 Series. This detailed information aids professionals in selecting the appropriate replacement that matches their system requirements.
Modernization Wiring Information:
Transitioning to modern controls like the RM7890A1015 may require rewiring existing systems. The guide emphasizes the importance of consulting the Modernization Wiring Information section to ensure proper installation and integration. This section provides insights into adapting current wiring setups to accommodate new control modules, thereby ensuring safety and functionality.
Footnotes and Additional Considerations:
The guide includes footnotes highlighting critical considerations, such as selecting the appropriate voltage, frequency, and timing specifications when choosing replacement controls. It also advises on the selection of compatible flame amplifiers, like the R7847A1025, R7847A1033, R7847B1023, or R7847B1031, depending on the specific application. These details are crucial for ensuring the seamless operation of upgraded burner management systems
We ship these products worldwide! Delivery is normally stock.
Request a Quote now or call us at 1-800-755-2883 for expert assistance.
Device To Be Replaced | Current Replacement |
7800 Series Replace- ment |
Wiring Number Number | Comments |
R177A | RA890F 1 | RM7890A1015 | power—1,2 limit—1-5 motor—3 ignition—4 controller—R,W,B detector—F,G | Remove Series 10 Controller and rewire. Same as RA890F except does not have “proof of flame” terminal (terminal 5 on RA890E,F). Requires Q270A Subbase with RA890F. Requires Q7800F1004 Subbase with RM7890A1015. |
R180A | RA890F 1 | RM7890A1015 | power—1,2 jumper—1-3 limit, main valve—4 controller—R,W,B detector—F,G |
Continuous pilot applications only. Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA 890F. Requires Q7800F1004 Subbase with RM7890A1015. |
R180B | RA890F 1 | RM7890A1015 | power -1,2 limit, main valve—5 motor, pilot valve—3 ignition—4 controller—R,W,B detector—F,G |
Functionality same as RA890F. Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F. Requires Q7800F1004 Subbase with RM7890A1015. |
R187A | RA890F 1 | RM7890A10105 | power—1,2 limit—1-5 motor—3 ignition—4 controller—R,W,B detector—F,G | Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F. Requires Q7800F1004 Subbase with RM7890A1015. |
R190B, RA190B | RA890F 1 | RM7890A1015 | See 180B | Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F. Requires Q7800F1004 Subbase with RM7890A1015. |
R190C | R4138C,D RA890H 4 | RM7838A,B RM7890B1014 | See Modernization Wiring Information section. | Used in W124 and ID051 panels. See Modernization Wiring Information section. |
R887A | RA890F 1 | RM7890A1015 | power—1,2 limit—1-5 motor—3 ignition—4 controller—T,T detector—F,G | Rewire. Requires Q270A Subbase with RA89OF. Requires Q7800f1004 Subbase with RM7890A1015. |
R890B, RA890B | RA890F 1 | RM7890A1015 | power—1,2 limit—1 motor,pilot valve—3 ignition—4 main valve—5 controller—6 jumper—T,T detector—F,G |
Requires Q7800F1004 Subbase with RM7890A1015. |
R890C, RA890C | RA890F 1 | RM7890A1015 | Same as R890B, RA890B | Requires Q7800Fl004 Subbase with RM7890A1015. |
RA890XB RA890XC | RA890F 1 | RM7890A1015 | Same as R890B, RA890B | Requires Q7800F1004 Subbase with RM7890A1015. |
RA890D | R4140M 1 | RM7840M1017 | Same as R890B, RA890B except controller always on terminal 6 and LF switch to T,T | Requires Q520A Subbase and R7247A Amplifier with R4140M. Requires Q7800L1001 Subbase and R7847A1009 or R7847B1007 Amplifier with RM7840M1017. |
Specifications | Current Rplcmt. |
SERIES 7800 Replacement |
|
RA890H,J,K OS Number to be Replaced 6 7 |
Voltage (50/60) |
||
RA890H1011 | 208 | None | None |
RA890H1029 | 240 | None | None |
RA890H1037 | 100 | None | None |
RA890H1045 | 220 | None | None |
RA890H1052 | 120 | H1052 | RM7890A1015 |
RA890J1008 | 120 | J1008 | None |
RA890J1016 | 120 | J1008 | None |
RA890J1024 | 208 | None | None |
RA890J1032 | 240 | None | None |
RA890K1006 | 120 | H1052 | RM7890A1015 |
Device To Be Replaced R4075A1009 |
Current Replace- ment NONE |
SERIES 7800 Replace- ment NONE |
R4075A1025 | NONE | NONE |
R4075A1033 R4075A1041 |
NONE NONE |
NONE NONE |
R4075A1058 R4075B1007 R4075B1015 R4075B1023 R4075B1031 R4075B1049 R4075B1056 R4075C1005 R4075C1013 R4075C1021 R4075C1039 R4075D1003 R4075E1000 R4075E1018 |
NONE R4075C1005 7 R4075C1005 7 R4075C1005 8 R4075C1005 7 R4075C1005 8 R4075C1005 R4075C1005 R4075C1013 R4075C1021 R4075C1039 R4075D1003 R4075E1000 NONE |
NONE RM7885A1015 6 RM7885A1015 6 RM7885A1007 13 RM7885A1015 6 RM7885A1007 13 RM7885A1015 6 RM7885A1015 6 NONE NONE NONE RM7885A1015 6 NONE NONE |
R4795A1099 R4795A1107 R4795C1004 R4795D1002 R4795D1010 R4795D1028 R4795D1036 R4795D1044 R4795D1051 R4795D1069 |
R4795A1099 R4795A1107 R4795A1016 2 R4795D1002 R4795A1002 None None None R4795D1051 R4795D1069 |
None None RM7895A1014 RM7895B1013 RM7895C1012 RM7895D1011 RM7895A1014 RM7895B1013 RM7895C1012 RM7895D1011 RM7895A1014RM7895B1013 RM7895C1012 RM7895D1011 None None None RM7895A1014RM7895B1013 RM7895C1012 RM7895D1011 None |
Device to be Replaced R7023A1005 | Current Replacement R7023B1003 | Series 7800 Replacement RM7823A1016 |
R7023A1021 | R7023B1052 | None |
R7023A1039 | R7023B1011 | None |
R7023A1047 | R7023B1003 5 | RM7823A1016 |
R7023A1054 | None | None |
R7023A1062 | R7023B1052 5 | None |
R7023A1070 | R7023B1037 | None |
R7023B1003 | R7023B1003 | RM7823A1016 |
R7023B1011 | R7023B1011 | None |
R7023B1029 | None | None |
R7023B1037 | R7023B1037 | None |
R7023B1045 | R7023B1003 5 | RM7823A1016 |
R7023B1052 | R7023B1052 | None |
R7023B1060 R7023C1001 |
R7023B1052 5 R7023C1001 |
NoneE RM7823A1016 |
R7023C1019 | R7023C1019 | RM7823A1016 |
R7023C1027 | R7023C1027 | None |
R7023C1035 | R7023C1035 | None |
R7023C1043 | R7023C1050 6 | None |
R7023C1050 R7023C1068 |
R7023C1050 None |
None RM7823A1016 |
R7023X1002 | None | None |
R7023X1010 R7023X1028 |
None R7023B1052 |
None None |
R7023X1036 | R7023B1052 5 | None |
R7023X1044 | R7023B1052 | None |
R7023X1051 R7023X1069 R7023X1077 R7023X1085 R7023X1093 |
R7023B1052 5 R7023B1052 5 7 None R7023B1052 5 7 R7023C1027 |
None None None None None |