The Honeywell SV9602P4816 Ignition SmartValve Control integrates gas flow control and electronic intermittent pilot sequencing in one unit. It offers various intermittent pilot sequences suitable for a range of gas-fired appliances such as furnaces, boilers, unit heaters, infrared heaters, space heaters, water heaters, decorative appliances, and commercial cooking units. This system simplifies control, enhances reliability, and ensures safety by combining critical functions in a compact design. It is adaptable to numerous applications, depending on the appliance manufacturer’s specifications, providing a versatile solution for modern gas appliance control needs.
Features
- Integral junction box provides NEMA 3 weather protection if motor is mounted in the upright position.
- Motor and circuitry operate from 24 Vac.
- Quick-connect terminals are standard–screw terminal adapter is available.
- Adapter bracket for matching shaft height of older motors is available.
- Motors have field adjustable stroke (90 to 160 degrees).
- Integral auxiliary switches are available factory mounted, or can be field added.
- All models have dual shafts (slotted and tapped on both ends).
- All models have auxiliary switch cams.
- Fixed torque throughout the entire voltage range.
Specifications
- Application Type: Electric
- Fail Safe Mode: Spring Return
- Control Signal: Proportional, 135 ohm
- Feedback: no
- Motor Shaft: Dual ended Shaft
- Stroke: Adjustable; 90 to 160 degrees, Symmetrical
- Torque Rating (lb-in.): 150 lb-in
- External Auxiliary Switches Available: Yes
- Frequency: 50 Hz, 60 Hz
- Power Consumption Driving (VA): 20 VA
- Electrical Connections: Quick Connect Terminals
- Shaft Dimensions (in.): .375 in
- Shaft Shape: Square
- Mounting: foot-mounted
- Dimensions: 6 7/16 in. high x 5 1/2 in. wide x 8 3/4 in. deep
- Temperature Range: -40 to 150F
- Deadweight Load on Shaft (Either End) (lb): 200 lbs
- Deadweight Load on Shaft (Combined on both shafts) (lb): 300 lbs
- Nominal Timing (sec): 30-60 sec
- Shaft Rotation (upon control signal increase): Clockwise (as viewed from power end) (normally closed)
- Auxiliary Switch Ratings AFL – 120 Vac: 7.2A
- Auxiliary Switch Ratings AFL – 240 Vac: 3.6A
- Auxiliary Switch Ratings ALR- 120 Vac: 43.2A
- Auxiliary Switch Ratings ALR- 240 Vac: 21.6A
- Includes: Transformer
Specs
Fail Safe Mode: |
Spring Return |
---|---|
Torque: |
60 lb-in |
Control Signal: |
Proportional |
Internal Aux Switch: |
1 |
Voltage: |
24v |
Mount: |
Foot |
Temperature Range: |
-40° to 150°F |
Timing: |
30-60 Seconds |