Description

The Honeywell V5055A1038 valve is designed for safety shutoff applications, controlling gas flow to commercial and industrial burners when used with V4055, V4062, and V9055 fluid power actuators. It ensures reliable gas flow management, enhancing operational safety and efficiency. The valve is constructed for robust performance in demanding environments and is essential for maintaining secure operation in burner systems. Its design accommodates easy integration with compatible Honeywell actuators, providing a versatile solution for various gas flow control needs in industrial applications. The V5055A1038 is a crucial component for enhancing the safety and reliability of burner systems.

Features

  • Integral junction box provides NEMA 3 weather protection if motor is mounted in the upright position.
  • Motor and circuitry operate from 24 Vac.
  • Quick-connect terminals are standard–screw terminal adapter is available.
  • Adapter bracket for matching shaft height of older motors is available.
  • Motors have field adjustable stroke (90 to 160 degrees).
  • Integral auxiliary switches are available factory mounted, or can be field added.
  • All models have dual shafts (slotted and tapped on both ends).
  • All models have auxiliary switch cams.
  • Fixed torque throughout the entire voltage range.

Specifications

  • Application Type: Electric
  • Fail Safe Mode: Non-Spring Return
  • Control Signal: Proportional, 135 ohm
  • Feedback: no
  • Motor Shaft: Dual ended Shaft
  • Stroke: Adjustable; 90 to 160 degrees, Asymmetrical
  • Torque Rating (lb-in.): 75 lb-in
  • External Auxiliary Switches Available: Yes
  • Frequency: 50 Hz, 60 Hz
  • Power Consumption Driving (VA): 20 VA
  • Electrical Connections: Quick Connect Terminals
  • Shaft Dimensions (in.): .375 in
  • Shaft Shape: Square
  • Mounting: foot-mounted
  • Dimensions: 6 7/16 in. high x 5 1/2 in. wide x 8 3/4 in. deep
  • Temperature Range: -40 to 150F
  • Deadweight Load on Shaft (Either End) (lb): 200 lbs
  • Deadweight Load on Shaft (Combined on both shafts) (lb): 300 lbs
  • Nominal Timing (sec): 30 -60 sec
  • Shaft Rotation (upon control signal increase): Clockwise (as viewed from power end) (normally closed)
  • Auxiliary Switch Ratings AFL – 120 Vac: 7.2A
  • Auxiliary Switch Ratings AFL – 240 Vac: 3.6A
  • Auxiliary Switch Ratings ALR- 120 Vac: 43.2A
  • Auxiliary Switch Ratings ALR- 240 Vac: 21.6A
  • Includes: Transformer

Specs

Fail Safe Mode:

Non-Spring Return

Control Signal:

Proportional

Torque:

75 lb-in

Voltage

120v

Internal Aux Switch:

1

Mount:

Foot

Temperature Range:

-40° to 150°F

Timing:

30-60 Seconds

 