A microprocessor-based flame safeguard programming control offering 2-line LCD alpha-numeric display (ED510) with local access to burner history, or LED indicator lights (EPD Programmers), modular design and communication capability.
The latest in flame safety technology is the Fireye line of burner controls. These combine safety, communication, and diagnostics into one compact, integrated, and affordable control. Fireye works with a range of commercial and industrial applications: burners, boilers, furnaces, kilns, and more. The energy conservation features significantly reduce unnecessary and wasteful purge related heat losses. For newer style burners or old, TCI Supply will help keep you safe and warm.
Request a Quote now or call us at 1-800-755-2883 for expert assistance.
Part Number | Description | Bulletin Number |
E110 | Control, consisting of EB700, 48-1836, EC600. 120 VAC. Display ordered separately. UL, FM, UL/c Approved. | E-1101 |
E120 | Same as E110 except 220 VAC, consisting of EB701, 48-1836, EC600. 220 VAC. FM Approval only. | E-1201 |
E210 | E-2101 | |
E211 | E-2101 | |
ED510 | 2 line x 16 character backlit LCD display with keypad. | ED-5101 |
EP113D | E-2101 | |
EP113E | E-2101 | |
EP113ES | E-2101 | |
EP113F | E-2101 | |
EP113NL | E-2101 | |
EP113NR | E-2101 | |
EP113SW | E-2101 | |
EP100F | Programmer. Selectable purge, selectable TFI, non-recycle, French language. | EP-1231 |
EP100S | Programmer. Selectable purge, selectable TFI, non-recycle, Spanish language. | EP-1231 |
EP160 | Programmer. Selectable purge (30 sec min.), 10 and 15 sec. TFI, non-recycle. | EP-1601 |
EP161 | Programmer. Selectable purge (30 sec min.), 10 and 30 sec. TFI, non-recycle. | EP-1601 |
EP163 | Programmer. Selectable purge (30 sec min.), selectable TFI via ED510 display, non-recycle. | EP-1601 |
EP165 | Programmer. Selectable purge (30 sec min.), pilot stabilization, non-recycle, 10 and 10 sec TFI. | EP-1601 |
EP166 | Programmer. Selectable purge (30 sec min.), pilot stabilization, non-recycle, 10 and 15 sec TFI programmer. | EP-1601 |
EP170 | Programmer. Selectable purge (30 sec min.), 5 and 10 sec. TFI, non-recycle, early spark termination. | EP-1601 |
EP174 | Programmer. Selectable purge (30 sec min.), 5 and 10 sec. TFI, non-recycle, early spark termination. M-D circuit must be proven through the completion of MTFI. | EP-1601 |
EP177 | Programmer. Early spark termination. ED510 to select purge (30 sec min.), prove air flow, prove high fire, prove low fire, and post purge. Early spark termination. Infinite hold on M-D circuit. | 133-666 |
EP200F | Programmer. Selectable purge (30 sec min.), selectable TFI, recycle, French language. | EP-1231 |
EP200S | Programmer. Selectable purge (30 sec min.), selectable TFI, recycle, Spanish language. | EP-1231 |
EP260 | Programmer. Selectable purge (30 sec min.), 10 and 15 sec. TFI, recycle. | EP-2601 |
EP265 | Programmer. Selectable purge (30 sec min.), pilot stabilization, recycle, 10 and 10 sec TFI. | EP-2601 |
EP270 | Programmer. Selectable purge (30 sec min.), 5 and 10 sec. TFI, recycle, early spark termination. | EP-2601 |
EP300F | Programmer. Selectable purge (30 sec min.), selectable recycle/non-recycle, 5 and 10 sec TFI, no modulation, French language. | EP-1231 |
EP300S | Programmer. Selectable purge (30 sec min.), selectable recycle/non-recycle, 5 and 10 sec TFI, no modulation, Spanish language. | EP-1231 |
EP380 | Programmer. Selectable purge (30 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle, no modulation. | EP-3801 |
EP381 | Programmer. Selectable purge (15 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle, no modulation. | EP-3801 |
EP382 | Programmer. Selectable purge (0 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle, no modulation. | EP-3801 |
EP383 | Programmer. Selectable purge, selectable TFI, selectable recycle/non-recycle via ED510, no modulation, no agency approvals. | EP-3801 |
EP387 | Programmer. Selectable purge (15 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle, no modulation, Infinite hold on M – D circuit.. | EP-3801 |
EP390 | Programmer. Selectable purge (90 sec min), 5 and 10 sec TFI, selectable recycle/non-recycle, no modulation. | EP-3801 |
EPD160 | EPD-1601 | |
EPD161 | EPD-1601 | |
EPD167 | EPD-1601 | |
EPD170 | EPD-1601 | |
EPD260 | EPD-2601 | |
EPD261 | EPD-2601 | |
EPD270 | EPD-2601 | |
EPD380 | EPD-3801 | |
EPD381 | EPD-3801 | |
EPD382 | EPD-3801 | |
EPD390 | EPD-3801 | |
E1R1 | Infrared autocheck amplifier, use with 48PT2. | EAMP1 |
E1R2 | Infrared autocheck amplifier, use with 48PT2. Special application only, consult factory. | EAMP1 |
E1R3 | Infrared autocheck amplifier, use with 48PT2. Solid fuels only. | EAMP1 |
ERT1 | Flame rectification amplifier, use with 45CM or 69ND. | EAMP1 |
EUV1 | Ultraviolet amplifier, use with UV1, UV2, UV8, UV90, or 45UV3. | EAMP1 |
EUVS4 | Ultraviolet self check amplifier. Use with 45UV5-1005, – 1007, -1008, -1009, or 55UV5-1007, -1009. | EAMP1 |
EP178 | Programmer. Keypad adjustable purge time, PTFI time, MTFI time, post purge time, early spark termination, pilot proving period, and indefinite hold on low fire start. For use with EDC1 and EDC2 amplifiers. | 133-732 |
EP378 | Programmer. Keypad adjustable purge time, PTFI time, MTFI time, post purge time, early spark termination, pilot proving period, and indefinite hold on low fire start. No modulation. For use with EDC1 and EDC2 amplifiers. | 133-732 |
EDC1 | Amplifier, for use with EP178 / EP378 and one or two 85UVF4-1QDWR, 85IRF4-1QDWR, or InSight flame scanners (with 59-497-020WR cable). | 133-732 |
EDC2 | Amplifier, for use with EP178 / EP378 and two 85UVF4-1QDWR, 85IRF4-1QDWR, or InSight flame scanners (with 59-497-020WR cable) to monitor pilot and main. Scanners automatically switched at appropriate time. | 133-732 |
E300 | Expansion module – use with E100/E110/E201/E211 | E-3001 |
E320 | Expansion module – use with E200/E210 or E120 (wire per E110 for E120). | E-3201 |
E350-3 | Expansion module cable, 3 ft length. | E-3001 |
E350-6 | Expansion module cable, 6 ft length. | E-3001 |
60-1950 | Expansion module wiring base. | E-3001 |
EB500 | Blank display module. | E-8001 |
EB700 | Replacement chassis for E100/E110 | E-1101 |
EB701 | Replacement chassis for E120. 120 VAC. FM Approval only. | E-1201 |
EB720 | E-2101 | |
EB721 | E-2101 | |
EC485 | RS232/RS485 converter with power supply and RJ12 jack. | EC-4851 |
EC600 | Red dust cover for E100/E110/E120/E200/E201/E210/E211. | E-1101 |
ED150-3 | Remote reset cable, 3 feet. | E-8001 |
ED150-6 | Remote reset cable, 6 feet. | E-8001 |
ED150-15 | Remote reset cable, 15 feet. | E-8001 |
ED150-25 | Remote reset cable, 25 feet. | E-8001 |
ED400 | Remote display housing (ED500). | E-8001 |
ED512-2 | RJ12 connector cable – 2 feet. | E-8002 |
ED512-4 | RJ12 connector cable – 4 feet. | E-8002 |
ED512-8 | RJ12 connector cable – 8 feet. | E-8002 |
ED550-2 | E500/remote display (ED500) cable, 18 inches. | E-5001 |
ED550-3 | E500/remote display (ED500) cable, 3 feet. | E-5001 |
ED550-6 | E500/remote display (ED500) cable, 6 feet. | E-5001 |
ED580-1 | ED510 remote display cable with RJ45 connector – 1 1/4 inch. | ED-5101 |
ED580-2 | ED510 remote display cable with RJ45 connector – 2 feet. | E-8002 |
ED580-4 | ED510 remote display cable with RJ45 connector – 4 feet. | E-8002 |
ED580-8 | ED510 remote display cable with RJ45 connector – 8 feet. | E-8002 |
ED600 | Multi-port cable adaptor for E100 accessories. | E-8001 |
ED610 | Multi-port cable adaptor for E110 accessories. | E-8002 |
ED611 | Multi-port cable adaptor for E110 accessories without ED510 reset. | E-8002 |
ED612 | Packaged with EC485, IC485 and UC485. PCB with RJ12 telephone jack. | – |
UC485 | USB RS232/RS485 converter. | UC-4851 |
14-64 | Schaffner Noise Filter | – |
19-112 | Ferrite core for ED512 / ED580 cables. | E-8002 |
33-426 | Captive nut for wiring base (60-1386, 60-1466). | – |
48-1805 | Mounting screw for E100, E200, E340, 25SU5-5011, -5166. | – |
48-1836 | Mounting screw for E110, E210, E211, E120. | – |
57AV4-5001 | Tester, 120 VAC, for use with C, D-Series and FLAME-MONITOR. | CP-47 |
60-1386-2 | Closed wiring base for surface mtg., use with D Series and FLAME-MONITOR. | D-1020 |
60-1466-2 | Open wiring base for cabinet mtg., use with D Series and FLAME-MONITOR. | D-1020 |
60-2107 | Service adaptor, wiring base with access to terminals. | SA-1027 |
60-2333 | Noise filter. OBSOLETE. Replaced by 14-64. | – |
61-4016 | Flame simulator (UV, IR, Flame rod) for 57AV4-5001 | – |
129-145-1 | Remote display (ED510) mounting kit with 4’ cable. | E-8002 |
129-145-2 | Remote display (ED510) mounting kit with 8’ cable. | E-8002 |
129-145-3 | Remote display (ED510) mounting kit with 2’ cable. | E-8002 |
129-152 | Ferrite core for ED512 / ED580 cables. – Replaced by 19- | E-8002 |