The Allen Bradley 1756-OW16IK module is a conformally-coated isolated contact module for Allen Bradley ControlLogix 5580 programmable controllers. The 1756-OW16IK module has 16 normally open individually isolated outputs. The pilot duty is the C300/R150 pilot duty. The operating voltage ranges are from 5 to 125 Volts DC and 10 to 240 Volts AC. The output voltage range is load-dependent: at 1 Amp, the output voltage range is from 5 to 30 Volts DC, at 0.5 Amps, the output is 48 Volts DC, at 0.22 Amps, the output is 125 Volts DC, at 1.5 Amps, the output is 120 Volts AC (at 50 to 60 Hertz), and at 0.75 Amps, the output voltage is 240 Volts AC (at 50 to 60 Hertz).

The current draw of the 1756-OW16IK module at both 5.1 Volts and 24 Volts is 150 milliamps. The power draw from the chassis backplane is 4.4 Watts and the peak power dissipation is 4.5 Watts. The module thermal dissipation is 15.35 BTU per hour. The minimum load current per point is 10 milliamps. The initial contact resistance is 100 milliohms at 6 Volts and 1 Amp. The expected contact life is 300 kilohertz resistive and 100 kilohertz inductive. The 1756-OW16IK module can be used with removable terminal blocks, including the 1756-TBCH and 1756-TBS6H removable terminal blocks. One slot in the rack is required for module installation. The operating temperature range for the 1756-OW16IK module is from 0 to 60 degrees Celsius. The continuous isolation voltage rating is 250 Volts. The module can be installed when the chassis power is applied. However, it is not advisable to do so because an electric arc can occur during the module insertion or removal process which could lead to explosions in hazardous locations.

 

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

TCI Supply is not an authorized Allen Bradley Distributor

Specification Sheet .pdf

 

 

Manufacturer Rockwell Automation
Brand Allen Bradley
Part Number/Catalog No. 1756-OW16IK
Series ControlLogix
Module Type Isolated Relay Output Module
Outputs 16-Point Individually Isolated
Operating Voltage 10-265 Volts AC, 5-150 Volts DC
Output Current 2, 0.5, 0.25 Amps
Listing This specification list has been compiled by DO Supply.
Maximum Output Delay Time 10 milliseconds
Contact Output 13 N.O.
Power Dissipation (Max) 4.5 Watts at 60 Celsius
Backplane Current at 5 Volts 150 milliamps
Backplane Current at 24 Volts 150 milliamps
Removeable Terminal Block(s) 1756-TBCH, 1756-TBS6H
Isolation Voltage 50 Volts Continuous
Enclosure None