Description

The Allen Bradley 1756-OF8 is an analog output module that is part of the ControlLogix platform. This analog module may be used to control and modulate electrical and field devices, transmit or re-transmits signals for interfacing with measuring and recording instruments or for any other purpose.

The 1756-OF8 comes with Eight (8) analog output channels configurable for +/-10VDC and 0-20 mA analog output signals. It has a resolution of 15 bits across 21 mA – 650 nA/bit and 15 bits across 10.4V – 320 µV/bit with open circuit, short circuit and overvoltage protection capability.
The 1756-OF8 uses R-Ladder DAC, monotonicity with no missing codes module conversion method and provides register data in the form of Integer mode (left justified, 2 s complement) IEEE 32-bit floating point. It has a scan time of 12 ms for floating point format and 8 ms for integer format.


Features

The 1756-OF8 requires removable terminal blocks for wiring of input signals. Appropriate terminal blocks are 1756-TBNH and 1756-TBSH. For 1756-TBNH, applicable wire size is 0.33…2.1 mm2 (22…14 AWG) solid or stranded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation max. for single wire connection and 0.33…1.3 mm2(22…16 AWG) solid or stranded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation max. for double wire connection. When 1756-TBSH is used, appropriate wire size is 0.33…2.1 mm2 (22…14 AWG) solid, or stranded shielded copper wire rated at 105 °C (221 °F), or greater, 1.2 mm (3/64 in.) insulation max. Only single wire connection is applicable for the 1756-TBSH.

When operational, it has an offset drift of 50 ppm/degrees Celsius and 0.1 ppm/degrees Celsius and temperature-dependent gain drift of 25 ppm/degrees Celsius and 50 ppm/degrees Celsius (current). The module has a scan time of 12 milliseconds for floating point and 8 milliseconds for integer and has an overall module error of 0.15% (in voltage mode) and 0.3% (in current mode). The1756-OF8 module has an isolation voltage of 250 Volts using reinforced insulation tested 1350 Volts AC for 2 seconds between the output channels and the backplane. It has a T4A (North America), T4 (ATEX), and T4 (IEC) temperature codes and comes in an open-style enclosure. The 1756-OF8’s operational temperature ranges between 0 and 60 degrees Celsius and it is designed to maintain its function at a shock rate of 30G and a vibration of 2G at 10 to 500 Hertz.


Specifications

Manufacturer Rockwell Automation
Overvoltage protection 24V DC
Enclosure None
Short circuit detection Electronically current limited to 21 mA or less
Open circuit detection Current only
Conversion Method R-Ladder DAC, monotonicity with no missing codes
Data Format Integer mode (left justified, 2 s complement) IEEE 32-bit floating point
Resolution 15bit
Output Voltage Range +/- 10VDC
Output Current Range 0-20 mA
No. of Outputs Eight (8) Current / Voltage
Brand Allen Bradley
Part Number/Catalog No. 1756-OF8
Series ControlLogix
Module Type Analog Output Module
Outputs 8 Current-Voltage
Backplane Current (5Volts) 140 milliamps
Backplane Current (24 Volts) 210 milliamps
Removable Terminal Blocks 1756-TBNH, 1756-TBSH
Power Dissipation (Max) 4.9 Watts at 60 Celsius
Removeable Terminal Block(s) 1756-TBNH, 1756-TBSH
Isolation Voltage 50 Volts Continuous

 

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Specification Sheet .pdf