The Siemens 540-100N TEC Terminal Box Controller is a Direct Digital Control (DDC) device designed for precise management of pressure-independent Variable Air Volume (VAV) systems in HVAC applications. It offers both stand-alone functionality and seamless integration into Siemens building automation networks, ensuring efficient environmental control and energy management.

Technical Specifications

  • Power Supply: 24 VAC, 50/60 Hz

  • Inputs:

    • Room temperature sensor

    • Optional duct temperature sensor

  • Outputs:

    • Electronic damper actuator control

    • Electronic valve actuator control

    • Optional relay module for additional control points

  • Communication: FLN (Field Level Network)

  • Mounting: Plenum-rated for installation in air-handling spaces

  • Operating Temperature Range: 32°F to 122°F (0°C to 50°C)

  • Humidity Range: 5% to 95% non-condensing

  • Dimensions: Standard Siemens TEC controller form factor

  • Enclosure: Plastic housing suitable for plenum use

Key Features

  • Advanced PID Control: Utilizes sophisticated Proportional-Integral-Derivative algorithms to maintain stable and accurate temperature regulation, minimizing fluctuations and optimizing comfort.

  • Versatile Application Support: Capable of managing various VAV configurations, including cooling-only, heating with electric or hot water reheat, and fan-powered systems, providing flexibility across different HVAC designs.

  • Stand-Alone or Networked Operation: Functions independently or as part of a Siemens building automation system, offering scalability for diverse project requirements.

  • Non-Volatile Memory: Stores setpoints and control parameters securely, ensuring data retention during power interruptions without the need for battery backup.

  • Auto Calibration: Eliminates the need for manual calibration, reducing maintenance efforts and ensuring consistent performance over time.

  • Airflow Reporting: Provides real-time airflow measurements in cubic feet per minute (cfm), aiding in system diagnostics and performance monitoring.

  • Flexible Mounting Options: Designed for plenum installation, accommodating various installation scenarios within air-handling spaces.

Compatible Components & Accessories

  • Room Temperature Sensors: Standard Siemens electronic room temperature sensors for accurate ambient measurements.

  • Duct Temperature Sensors: Optional sensors for monitoring supply or return air temperatures within ductwork.

  • Electronic Damper Actuators: Compatible actuators for precise control of air dampers in VAV applications.

  • Electronic Valve Actuators: Actuators for modulating control of heating or cooling valves, facilitating effective temperature management.

  • Relay Modules: Optional modules to expand control capabilities, allowing integration of additional equipment or functions.

Industry Applications

  • Commercial Buildings: Optimizes occupant comfort and energy efficiency in office spaces, retail establishments, and other commercial environments.

  • Educational Institutions: Provides precise environmental control in classrooms, lecture halls, and administrative areas, enhancing learning conditions.

  • Healthcare Facilities: Maintains stringent temperature and airflow requirements in patient rooms, operating theaters, and laboratories, ensuring compliance with health standards.

  • Hospitality Sector: Enhances guest comfort in hotels and conference centers through reliable and responsive HVAC control.

  • Industrial Settings: Controls environmental conditions in manufacturing areas, warehouses, and clean rooms, supporting product quality and worker safety.

Installation & Maintenance Notes

  • Power Requirements: Ensure a stable 24 VAC power supply is available, adhering to the specified voltage and frequency parameters.

  • Sensor Placement: Install room and duct temperature sensors in locations that accurately represent the controlled environment for optimal feedback and control.

  • Actuator Compatibility: Verify that connected damper and valve actuators are compatible with the controller’s output specifications to ensure proper operation.

  • Network Integration: When connecting to a building automation network, follow Siemens guidelines for FLN communication wiring and configuration to maintain reliable data exchange.

  • Environmental Considerations: Install the controller in environments within the specified temperature and humidity ranges to prevent operational issues.

  • Regular Inspection: Periodically check electrical connections, sensor functionality, and actuator performance to identify and address potential issues proactively.

  • Firmware Updates: Consult Siemens support resources to determine if firmware updates are available to enhance functionality or address known issues.

Request a Quote now or call us at 1-800-755-2883 for expert assistance.