The Siemens Milltronics Hydroranger is an ultrasonic level controller designed for non-contact level measurement in water and wastewater applications. This version does not include keypads, making it ideal for remote configuration and integration into SCADA systems. It is widely used for monitoring water levels, open-channel flow, and differential level measurement in industrial and municipal applications.
Technical Specifications
- Manufacturer: Siemens Milltronics
- Model: Hydroranger (Without Keypads)
- Measurement Type: Ultrasonic Level Control
- Range: Up to 50 ft (15 m), depending on transducer selection
- Control Outputs: Up to 6 relays for pump and alarm control
- Communication Interface: HART, PROFIBUS DP, MODBUS RTU
- Power Supply: 100-230V AC or 12-30V DC
- Accuracy: ±0.15% of range or ±6 mm (whichever is greater)
- Temperature Compensation: Automatic compensation with an integrated sensor
- Environmental Protection: IP65 (NEMA 4X) enclosure for harsh conditions
- Mounting Configuration: Wall-mounted or DIN rail-mounted
- Certifications: CE, CSA, UL approved for industrial use
Key Features
- Non-contact ultrasonic level measurement for liquids and solids
- No keypad interface – remote configuration via external controllers
- Supports up to 6 relay outputs for pump and alarm control
- Ideal for open-channel flow and differential level applications
- High accuracy with automatic temperature compensation
- Robust design with IP65/NEMA 4X protection for harsh environments
Compatible Siemens Components
- Siemens Echomax Ultrasonic Transducers (e.g., XRS-5, ST-H, XPS-10)
- Siemens SIMATIC SCADA systems for remote monitoring
- Siemens S7-1200 and S7-1500 PLCs for process automation
- Siemens Process Instrumentation Software for configuration
Industry Applications
- Water and wastewater treatment plants
- Municipal stormwater and sewer monitoring
- Reservoir and tank level monitoring
- Open-channel flow measurement
- Industrial process control for bulk liquid storage
Installation & Operational Notes
- Ensure proper alignment with the ultrasonic transducer for accurate readings
- Connect to external SCADA or PLC systems for remote operation
- Use appropriate relay configurations for pump and alarm control
- Perform regular maintenance to clean transducers and prevent signal interference
- Follow Siemens installation guidelines for optimal performance
We ship this product worldwide! Delivery is normally stock.