The Fireye® BurnerLogix™ System is a microprocessor based burner management control system designed to provide the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas, and combination fuel burners. The latest in flame safety technology is the Fireye line of burner controls. These combine safety, communication, and diagnostics into one compact, integrated, and affordable control. Fireye works with a range of commercial and industrial applications: burners, boilers, furnaces, kilns, and more. The energy conservation features significantly reduce unnecessary and wasteful purge related heat losses. For newer style burners or old, TCI Supply will help keep you safe and warm.
Request a Quote now or call us at 1-800-755-2883 for expert assistance.
Part Number | Description | Bulletin Number |
YB110UV | Chassis, 120 VAC, 50/60 Hz with UV non self-check amplifier. UL, FM, CE Approved. | BL-1001 |
YB110UVSC | Chassis, 120 VAC, 50/60 Hz with UV self-check amplifier. UL, FM, CE Approved. | BL-1001 |
YB110IR | Chassis, 120 VAC, 50/60 Hz with IR Auto-Check amplifier. UL, FM, CE Approved. | BL-1001 |
YB110IR2 | Chassis, 120 VAC, 50/60 Hz with IR Auto-Check amplifier. UL, FM, CE Approved. | BL-1001 |
YB110FR | Chassis, 120 VAC, 50/60 Hz with flame rectification amplifier. UL, FM, CE Approved. | BL-1001 |
YB110DC | Chassis, 120 VAC, 50/60 Hz with direct coupled amplifier for use with Phoenix and Insight scanners. UL, FM, CE Approved. | BL-1001 |
YB230UV | Chassis, 230 VAC, 50/60 Hz with UV non self-check amplifier. FM, CE Approved. | BL-1001 |
YB230UVSC | Chassis, 230 VAC, 50/60 Hz with UV self-check amplifier, FM, CE Approved. | BL-1001 |
YB230IR | Chassis, 230 VAC, 50/60 Hz with IR Auto-Check amplifier. FM, CE Approved. | BL-1001 |
YB230IR2 | Chassis, 230 VAC, 50/60 Hz with IR Auto-Check amplifier. UL, | BL-1001 |
YB230FR | Chassis, 230 VAC, 50/60 Hz with flame rectification amplifier. FM, CE Approved. | BL-1001 |
YB230DC | Chassis, 230 VAC, 50/60 Hz with direct coupled amplifier for use with Phoenix and Insight scanners. FM, CE Approved. | BL-1001 |
BLV512 | Keypad/Display, 2 line X 16 characters, VACUUM FLUORESCENT DISPLAY (VFD), with cable. Operates -40F (-40C) to 140F (+60C). | BD-5001 |
BLL510 | Keypad/Display, 2 line X 16 characters, LIQUID CRYSTAL DISPLAY (LCD), with cable. Operates -4F (-20C) to +140F (+60C). | BD-5001 |
129-178-4 | Kit, remote mounting, BurnerLogix display, 4 ft. cable, provides NEMA 4 protection | 133-675 |
129-178-8 | Kit, remote mounting, BurnerLogix display, 8 ft. cable, provides NEMA 4 protection | 133-675 |
BLD500 | Blank display module for BurnerLogix. | – |
YP100 | Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 4 second FFRT | YP-1001 |
YP102 | Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 2 second FFRT | YP-1001 |
YP113 | Keypad selectable parameters, open/closed damper proving, 10 sec low fire start time, non-recycle operation, fixed TFI times, pilot proving, modulation, 1 second FFRT. Required for CE applications. | YP-1001 |
YP115 | Keypad selectable parameters, includes 0 sec purge time, fixed0 sec low fire start time, non-recycle operation, fixed TFI times, pilot proving, modulation, open/closed damper proving, 1 second FFRT. Required for CE applications. | YP-1001 |
YP118 | Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, indefinite pilot hold, revert to pilot from auto, 1 second FFRT | YP-1001 |
YP138 | Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 4 sec FFRT. Powered inputs provide indefinite hold, pilot hold, revert to pilot from auto. | YP-1001 |
YP183 | Keypad selectable parameters, non-recycle operation, modulation, open/closed damper proving, 4 sec FFRT. Unpowered inputs provide indefinite hold, pilot hold, revert to pilot from auto. Provides purge complete output. | YP-1001 |
YP200 | Keypad selectable parameters, recycle operation, modulation, 4 second FFRT | YP-1001 |
YP202 | Keypad selectable parameters, recycle operation, modulation, 2 second FFRT | YP-1001 |
YP300 | Keypad selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT | YP-1001 |
YP302 | Keypad selectable parameters, recycle operation, low fire start, early spark termination, 2 second FFRT | YP-1001 |
ZB110UV | Chassis, 120 VAC, 50/60 Hz with burner control functions, contains UV non self-check amplifier | BLZ-1001 |
ZB110UVSC | Chassis, 120 VAC, 50/60 Hz with burner control functions, contains UV self-check amplifier | BLZ-1001 |
ZB110IR | Chassis, 120 VAC, 50/60 Hz with burner control functions, contains IR Autocheck amplifier | BLZ-1001 |
ZB110IR2 | Chassis, 120 VAC, 50/60 Hz with burner control functions, contains high sensitivity IR Autocheck amplifier. Special application only, consult factory. | BLZ-1001 |
ZB230UV | Chassis, 230 VAC, 50/60 Hz with burner control functions, contains UV non self-check amplifier | BLZ-1001 |
ZB230UVSC | Chassis, 230 VAC, 50/60 Hz with burner control functions, contains UV self-check amplifier | BLZ-1001 |
ZB230IR | Chassis, 230 VAC, 50/60 Hz with burner control functions, contains IR Autocheck amplifier | BLZ-1001 |
ZB230IR2 | Chassis, 230 VAC, 50/60 Hz with burner control functions, contains high sensitivity IR Autocheck amplifier. Special application only, consult factory. | BLZ-1001 |
BLPS-15 | Pressure transducer, 0-15 psi (0-1030 mb), 4-20 mA output linear with pressure. ¼” NPT mounting. Screw terminal connections and conduit adapter cover. | BLZPTS-1 |
BLPS-30 | Pressure transducer, 0-30 psi (0-2070 mb), 4-20 mA output linear with pressure. ¼” NPT mounting. Screw terminal connections and conduit adapter cover. | BLZPTS-1 |
BLPS-200 | Pressure transducer, 0-200 psi (0-13.8 Bar), 4-20 mA output linear with pressure. ¼” NPT mounting. Screw terminal connections and conduit adapter cover. | BLZPTS-1 |
BLPS-300 | Pressure transducer, 0-300 psi (0-20.7 Bar), 4-20 mA output linear with pressure. ¼” NPT mounting. Screw terminal connections and conduit adapter cover. | BLZPTS-1 |
TS350-2 | Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 420 mA output, linear with temperature. Insertion length is 2 inches. Stainless steel thermowell included with 1/2” – 14 NPT mounting. | BLZPTS-1 |
TS350-4 | Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 420 mA output, linear with temperature. Insertion length is 4 inches. Stainless steel thermowell included with 1/2” – 14 NPT mounting. | BLZPTS-1 |
TS350-8 | Temperature sensor, Range 32°F to 350°F (0°C to 176°C), 420 mA output, linear with temperature. Insertion length is 8 inches. Stainless steel thermowell included with 1/2” – 14 NPT mounting. | BLZPTS-1 |
TS752-2 | Temperature sensor, Range 32°F to 752°F (0°C to 400°C), 420 mA output, linear with temperature. Insertion length is 2 inches. Stainless steel thermowell included with 1/2” – 14 NPT mounting. | BLZPTS-1 |
TS752-4 | Temperature sensor, Range 32°F to 752°F (0°C to 400°C), 420 mA output, linear with temperature. Insertion length is 4 inches. Stainless steel thermowell included with 1/2” – 14 NPT mounting. | BLZPTS-1 |
TS752-8 | Temperature sensor, Range 32°F to 752°F (0°C to 400°C), 420 mA output, linear with temperature. Insertion length is 8 inches. Stainless steel thermowell included with 1/2” – 14 NPT mounting. | BLZPTS-1 |
YZ300 | Interlock annunciator, provides first out annunciation. 120 VAC operation. | YZEM-3001 |
YZ320 | Interlock annunciator, provides first out annunciation. 230 VAC operation. | YZEM-3001 |
60-2872-1 | YZ300 wiring base, terminal blocks, closed with knockouts. | YZEM-3001 |
60-2874-1 | YZ300 wiring base, terminal blocks, open end. | YZEM-3001 |
YZ300P | Windows based software for programming custom messages. | – |
ED580-2 | YB110 or ZB110 to YZ300 interconnection cable, 2’ length. | E-8002 |
ED580-4 | YB110 or ZB110 to YZ300 interconnection cable, 4’ length. | E-8002 |
ED580-8 | YB110 or ZB110 to YZ300 interconnection cable, 8 length. | E-8002 |
23-197 | Replaceable fuse for BurnerLogix YB110 chassis. Wickman fuse #19378-071-K, 10 amp. | – |
57YB4-5000 | Tester, 120 VAC, for use with BurnerLogix YB control. | YBT-1000 |