The Asco SC8210G002 Solenoid Valve (SC8210G2) is a pilot-operated, two-way normally closed valve designed for general-purpose fluid control in air, water, and light oil systems. Built with a brass body and a DIN 43650 connection, this SC Class F high-temperature valve ensures reliable operation in demanding industrial applications.
For general-purpose valves, see Asco 8210G002.
Technical Specifications
- Valve Type: Pilot Operated, Normally Closed, 2-way
- Pipe Size: ½” NPT
- Flow Factor (Cv): 4.0
- Operating Pressure Differential:
- Air/Inert Gas: 5 to 200 psi (AC)
- Water: 5 to 150 psi (AC)
- Light Oil: 5 to 135 psi (AC)
- Maximum Fluid Temperature:
- AC: 180°F (82°C)
- Body Material: Brass
- Seal Material: NBR (Nitrile)
- Voltage Options:
- AC (60Hz): 120V
- AC (50Hz): 110V
- Watt Rating:
- AC: 6.1 watts
- Coil Insulation Class: SC Class F – High Temperature
- Solenoid Enclosure:
- Standard: DIN 43650 Connection
- Optional: Explosionproof & Watertight (Types 3, 7, 9)
Key Features and Functionality
- SC Class F High-Temperature Coil: Designed for demanding industrial applications.
- High Flow Rate: Ensures efficient fluid movement with minimal pressure drop.
- Compact DIN 43650 Connection: Allows for quick coil replacement and easy maintenance.
- Brass Body Construction: Provides excellent durability and corrosion resistance.
- Versatile Pressure Range: Operates at up to 200 psi for air and 150 psi for water.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Rebuild Kit (302273)
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Industrial Water Control: Regulates fluid flow in automated water systems.
- Air Compressors: Controls air flow in pneumatic systems.
- Pumps: Manages liquid transfer processes efficiently.
- HVAC Systems: Supports heating, ventilation, and cooling applications.
- Automated Machinery: Ensures precise fluid control in industrial automation.
Compliance and Approvals
- CSA Certified
- Meets CE Directives
- NEMA 4X, IP65 Rated
Installation and Operational Notes
- Ensure proper voltage selection for system compatibility.
- Mount in any direction for flexible installation.
- Regularly inspect for seal wear and coil integrity.
- Use only within specified temperature and pressure ranges.
We ship this product worldwide! Delivery is normally stock.