ASCO JB8214050C Solenoid Valve
ASCO JB8214050C Solenoid Valve

The Asco JB8214050C Solenoid Valve is a normally closed, pilot-operated gas shutoff valve designed with a double-disc construction for redundant sealing. Featuring visual position indication and a proof of closure switch, it ensures high-integrity shutoff in fuel gas systems. Ideal for large commercial burners and industrial heating systems requiring reliable safety interlocks.

Technical Specifications

  • Valve Type: Pilot Operated, Normally Closed, 2-Way
  • Pipe Size: 1” NPT
  • Flow Factor (Cv): 21
  • Gas Capacity: 1,119,000 Btu/hr
  • Operating Pressure Differential:
    • Fuel Gas: 0 to 5 psi
  • Maximum Fluid Temperature: 125°F (52°C)
  • Body Material: Aluminum
  • Seal Material: NBR
  • Voltage Options:
    • AC (60Hz): 24, 120, 240V
    • AC (50Hz): 110, 220V
  • Watt Rating:
    • AC: 20 watts
  • Coil Insulation Class: F
  • Solenoid Enclosure:
    • Standard: RedHat metal solenoid enclosure
    • Type: Type 1 General Purpose Junction Box with two 7/8″ knockouts

Key Features and Functionality

  • Double Disc Design: Ensures redundant shutoff for added safety.
  • Visual Position Indication: Shows valve open or closed status.
  • Proof of Closure Switch: 1 Amp contact for circuit feedback.
  • Zero Differential Start: Operates from 0 psi line pressure.
  • Fuel Gas Tested Body: Die-cast aluminum for strength and corrosion resistance.

Compatible Components and Related Parts

  • ASCO RedHat II Coil Series
  • ASCO Mounting Brackets
  • ASCO Seal Kit for 8210 Series
  • ASCO Junction Box Wiring Accessories

Industry Applications

  • Commercial Combustion Systems: Shuts off gas to large burners.
  • Industrial Heating Equipment: Used in boiler and oven control.
  • Gas Distribution Networks: Safety valve with proof of closure feedback.
  • Refinery Burner Trains: Visual and electrical assurance of shutdown.
  • HVAC Systems: For secure, monitored fuel gas shutdown.

Compliance and Approvals

  • UL Listed
  • FM Approved
  • CSA Certified

Installation and Operational Notes

  • Install the valve with the solenoid in an upright vertical position.
  • Do not install the valve in a location where it may be subject to excessive vibration.
  • Pipe strain must be avoided — use wrenching only on the valve body, not on the solenoid.
  • Apply pipe compound sparingly to male pipe threads only; avoid overtightening.
  • Electrical conduit and grounding must comply with local and national codes.

 

We ship this product worldwide! Delivery is normally stock.

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Get A Quote

Fill in the form below, or call us now at 1-800-755-2883

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Full Product Catalog

See our comprehensive product catalog!