Asco EV8316G384V Solenoid Valve
Asco EV8316G384V Solenoid Valve

The Asco EV8316G384V Solenoid Valve is a 3-way, normally closed valve with a 1/2″ NPT stainless steel body designed for air or inert gas use. It features a low-power 24 VDC coil that performs reliably in high ambient temperatures. When externally piloted, it can operate with zero inlet pressure.

Technical Specifications

  • Pipe Size: 1/2″ NPT
  • Flow Factor (Cv):
    • Pressure to Cylinder: 4.0
    • Cylinder to Exhaust: 4.0
  • Valve Type: 3-Way, Normally Closed, Pilot-Operated
  • Operating Pressure Differential:
    • Air/Inert Gas: 0 to 140 psi
  • Maximum Fluid Temperature: 175°F (80°C)
  • Body Material: 316 Stainless Steel
  • Seal Material: FKM (Main Valve), NBR (Pilot)
  • Watt Rating: Low Power Coil (Special)
  • Coil Insulation Class: F
  • Solenoid Enclosure:
    • Explosionproof and Watertight (Types 3-9), NEMA 4X, IP65 (included)

Key Features and Functionality

  • Explosionproof Certified: EV prefix coil rated for hazardous areas.
  • Low-Power Operation: Ideal for PLC control and battery systems.
  • Zero Minimum Pressure: External pilot enables 0 psi startup.
  • High Ambient Tolerance: It can operate safely up to 175°F (80°C).
  • Dual Cv Design: Equal flow from pressure and exhaust ports.

Compatible Components and Related Parts

  • ASCO RedHat II Low Power Coil Series
  • ASCO Stainless Steel Mounting Brackets (MB suffix)
  • ASCO Seal Kit for 8316 Series
  • ASCO Explosionproof Conduit Fittings

Industry Applications

  • Hazardous Area Automation: Safe actuation in explosive environments.
  • Control Panels: Reliable switching in temperature-sensitive enclosures.
  • Battery-Powered Systems: Reduced drain for remote control use.
  • Valve Actuation: Accurate air switching to cylinders and actuators.
  • OEM Air Skids: Compact, corrosion-resistant pneumatic routing.

Compliance and Approvals

  • CSA Certified
  • Nonincendive for Class I, Division 2 (UL E25549)
  • CE Compliant

Installation and Operational Notes

  • Use with clean, dry air or inert gas filtered to 50 microns or better.
  • Ensure the dew point is at least 18°F (–8°C) below minimum ambient temperature.
  • Instrument air per ANSI/ISA S7.3-1975 (R1981) is acceptable.
  • Requires external pilot for 0 psi operation; internal pilot needs 15 psi minimum.
  • May be mounted in any position; optional stainless steel brackets available (suffix MB).

 

We ship this product worldwide! Delivery is normally stock.

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Get A Quote

Fill in the form below, or call us now at 1-800-755-2883

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Full Product Catalog

See our comprehensive product catalog!