The Asco 8262G264 Solenoid Valve is a normally open, direct-acting 2-way valve engineered for low-pressure air, water, and light oil control in systems that must remain open when de-energized. With a 0.83 Cv rating, this model supports higher flow rates through a 1/4″ NPT port, making it suitable for compact utility lines and OEM fluid circuits.
Technical Specifications
- Valve Type: Direct Acting, Normally Open, 2-Way
- Pipe Size: 1/4″ NPT
- Flow Factor (Cv): 0.83
- Operating Pressure Differential:
- Max Air/Inert Gas: 45 psi (AC), 25 psi (DC)
- Max Water: 45 psi (AC), 20 psi (DC)
- Max Light Oil: 40 psi (AC), 20 psi (DC)
- Maximum Fluid Temperature:
- AC: 180°F (82°C)
- DC: 150°F (66°C)
- Body Material: Brass
- Seal Material: NBR
- Voltage Options:
- AC: 24, 120, 240, 480 V (60 Hz); 110, 220 V (50 Hz)
- DC: 6, 12, 24, 120, 240 V
- Watt Rating:
- AC: 10.1/F
- DC: 11.6/F
- Solenoid Enclosure:
- Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X
- Optional: Explosionproof and Watertight (Types 3, 3S, 4, 4X, 6, 6P, 7, and 9)
Key Features and Functionality
- Normally-Open Configuration: Allows flow when the solenoid is de-energized.
- 0.83 Cv Flow Rating: Supports higher flow rates in low-pressure circuits.
- Direct-Acting Operation: Opens without requiring upstream pressure.
- Compact Brass Assembly: Ideal for tight enclosures and manifold designs.
- Fluid Compatibility: Rated for air, water, and light oil service.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8262 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Car Wash Systems: Controls open flow to rinse or blower systems.
- Laundry Equipment: Activates fluid lines in powered-down states.
- Compressors and Pumps: Used in bypass or drain loops.
- Boilers and Burners: Maintains flow path for purge or venting functions.
- Food Processing Equipment: Enables fluid evacuation or CIP line flow.
Compliance and Approvals
- UL Listed for General Purpose Valve
- CSA Certified
- Meets Applicable CE Directives
Installation and Operational Notes
- Verify that the media is compatible with NBR seals and check the temperature limits.
- For optimal performance, mount the solenoid in an upright position.
- Install an inlet strainer to prevent clogging and ensure clean operation.
- Only seal the male threads, and avoid overtightening the valve body.
- Isolate the pressure and electrical supply before performing any servicing.