The Asco 8262G262 Solenoid Valve is a normally open, direct-acting two-way valve designed for low to moderate pressure fluid control in systems that require continuous flow when power is off. This valve features NBR seals, a Cv rating of 0.35, and is made of compact brass. It is perfect for use with compressed air, water, and light oil in control cabinets, utility circuits, and compact process assemblies.
Technical Specifications
- Valve Type: Direct Acting, Normally Open, 2-Way
- Pipe Size: 1/4″ NPT
- Flow Factor (Cv): 0.35
- Operating Pressure Differential:
- Max Air/Inert Gas: 130 psi (AC), 80 psi (DC)
- Max Water: 110 psi (AC), 60 psi (DC)
- Max Light Oil: 100 psi (AC), 60 psi (DC)
- Maximum Fluid Temperature:
- AC: 180°F (82°C)
- DC: 150°F (66°C)
- Body Material: Brass
- Seal Material: NBR
- Voltage Options:
- AC: 24, 120, 240, 480 V (60 Hz); 110, 220 V (50 Hz)
- DC: 6, 12, 24, 120, 240 V
- Watt Rating:
- AC: 10.1/F
- DC: 11.6/F
- Solenoid Enclosure:
- Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X
- Optional: Explosionproof and Watertight (Types 3, 3S, 4, 4X, 6, 6P, 7, and 9)
Key Features and Functionality
- Normally-Open Configuration: Allows flow when the solenoid is de-energized.
- Direct-Acting Design: Operates without a minimum pressure differential.
- Brass Body with NBR Seals: Suitable for air, water, and light oil service.
- Moderate Pressure Capability: Air systems are rated up to 130 psi.
- Compact Footprint: Designed for space-limited control panels.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8262 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Car Wash Systems: Controls rinse or dryer air in de-energized state.
- Laundry Equipment: Opens water or detergent lines on power loss.
- Pumps and Compressors: Vents or drains during idle system states.
- Boilers and Burners: Maintains open flow in purge or pilot lines.
- Food Processing Equipment: Enables CIP line access or system drainage.
Compliance and Approvals
- UL Listed for General Purpose Valve
- CSA Certified
- Meets Applicable CE Directives
Installation and Operational Notes
- Verify seal compatibility with system media and temperature.
- Mount the solenoid vertically when possible to reduce debris accumulation.
- A strainer or filter should be used on the inlet to protect internal valve components.
- Do not apply pipe compound to valve threads; use it on male threads only.
- Disconnect power and relieve system pressure before servicing.
Series Catalog