The Asco 8262G214 Solenoid Valve (8262G214) is a direct-acting, normally closed valve engineered for shutoff in extreme-pressure conditions up to 2200 psi. Its stainless steel body ensures durability in corrosive or outdoor environments. The low Cv design enables precise control in pilot circuits, metering lines, and gas isolation service where compact form and pressure integrity are essential.
Technical Specifications
- Valve Type: Direct Acting, Normally Closed, 2-Way
- Pipe Size: 1/4″ NPT
- Flow Factor (Cv): 0.06
- Operating Pressure Differential:
- Max Air/Inert Gas: 2200 psi (AC)
- Max Water: 2000 psi (AC)
- Max Light Oil: 1100 psi (AC)
- Maximum Fluid Temperature:
- AC: 140°F (60°C)
- Body Material: Stainless Steel
- Seal Material: NBR
- Voltage Options: AC: 24, 120, 240, 480 V (60 Hz); 110, 220 V (50 Hz)
- Watt Rating:
- AC: 10.1/F
- Solenoid Enclosure:
- Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X
- Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9
Key Features and Functionality
- Stainless Steel Body: Protects against corrosion in exposed environments.
- High-Pressure Capability: Rated for air up to 2200 psi.
- Low Cv Precision: Suitable for metered gas and liquid shutoff.
- Direct-Acting Response: Functions without pilot or line pressure.
- Orientation-Independent: Can be mounted in any position.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8262 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Oil and Gas: Used in fuel gas trains and high-pressure panels.
- Chemical Processing: Isolates dosing or pilot gas lines.
- Water and Wastewater: High-pressure shutoff in brine or chlorinated flow.
- General Industrial and OEM: Integrates into tight control skids or test rigs.
- Cryogenic and Low-Temp: Suitable for vapor-phase nitrogen and inert gases.
Compliance and Approvals
- CSA Certified
- Meets Applicable CE Directives
- FM Approved
- UL Listed: General Purpose Valve
Installation and Operational Notes
- Verify the catalog number, voltage, pressure, and media before installation.
- Pipe to correct ports; use compound on male threads only.
- Mountable in any position; an upright solenoid is preferred.
- Install a filter or strainer close to the valve inlet.
- Depressurize and disconnect power before cleaning or maintenance.