The Asco 8262G094 Solenoid Valve (8262G94) is a direct-acting, normally open, 2-way stainless steel valve designed for on/off control in systems handling corrosive or aggressive media. Its zero-pressure differential design supports flow-through applications in compressed air, chemical rinse, and process purge systems where flow must be maintained in the de-energized state.
Technical Specifications
- Valve Type: Direct Acting, Normally Open, 2-Way
- Pipe Size: 1/8″ NPT
- Flow Factor (Cv): 0.15
- Operating Pressure Differential:
- Max Air/Inert Gas: 275 psi (AC), 190 psi (DC)
- Max Water: 200 psi (AC), 110 psi (DC)
- Max Light Oil: 150 psi (AC), 110 psi (DC)
- Maximum Fluid Temperature: AC: 180°F (82°C), DC: 120°F (49°C)
- Body Material: Stainless Steel
- Seal Material: NBR
- Voltage Options:
- AC: 24, 120, 240, 480 V (60 Hz); 110, 220 V (50 Hz)
- DC: 6, 12, 24, 120, 240 V
- Watt Rating:
- AC: 6.1/F
- DC: 10.6/F
- Solenoid Enclosure:
- Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X
- Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9
Key Features and Functionality
- Corrosion-Resistant Construction: Stainless steel body supports aggressive media.
- Direct Acting Valve: Functions without pressure assistance.
- Normally-Open Flow Path: Flow is enabled when the solenoid is de-energized.
- Low Internal Volume: Reduces residual fluid and response lag.
- High Pressure Capability: Rated for compressed air up to 275 psi (AC).
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8262 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Compressed Air Systems: Maintains open air release paths during shutdown.
- Dishwashing and Rinse Systems: Allows flow of chemicals or rinse water when idle.
- Pump Skids: Keeps bypass or relief paths open when the control signal is off.
- Burner Assemblies: Open the vent or exhaust port during the standby condition.
- Food Processing Equipment: Controls the flow of cleaning agents or neutralizing solutions.
Compliance and Approvals
- UL Listed for General Purpose
- CSA Certified
- CE Compliant
Installation and Operational Notes
- Verify pressure, voltage, and fluid compatibility before installation.
- Connect the inlet and outlet as marked on the valve body.
- Best performance achieved with the solenoid mounted upright.
- Install a strainer or filter at the inlet to prevent clogging.
- Depressurize the system and disconnect power before servicing.