The Asco 8222G005 Solenoid Valve (8222G5) is a pilot-operated, normally closed steam valve for high-pressure thermal systems. It handles up to 200 psi at 388°F and opens with as little as five psi inlet pressure. A 3/4″ NPT inlet and a 4.6 Cv flow rating make it suitable for delivering controlled steam to sealed, high-load applications.
Technical Specifications
- Valve Type: Pilot Operated, Normally Closed, 2-Way
- Pipe Size: 3/4″ NPT
- Flow Factor (Cv): 4.6
- Operating Pressure Differential:
- Steam: 5 to 200 psi
- Maximum Fluid Temperature:
- AC (Steam): 388°F (198°C)
- Body Material: Brass
- Seal Material: TFE/P, EPDM, or PTFE
- Voltage Options:
- AC (60Hz): 24, 120, 208, 240, 480 V
- AC (50Hz): 110, 220, 240, 480 V
- DC: 12, 24, 48, 120 V
- Watt Rating:
- AC: 10.1 watts
- Coil Insulation Class: H
- Solenoid Enclosure:
- Standard: NEMA 4X, IP65 (Watertight, Corrosion-Resistant)
- Optional: Explosionproof & Watertight (Types 3-9), Raintight (Types 3, 7, 9)
Key Features and Functionality
- High Pressure Capability: Rated up to 200 psi for steam systems.
- Elevated Temperature Tolerance: Performs in environments up to 388°F.
- Reliable Pilot Operation: Maintains shutoff at higher flow loads.
- Moderate Flow Performance: Supports 4.6 Cv thermal media delivery.
- Durable Brass Construction: Withstands demanding high-temp applications.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8220/8222 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Sterilizers: Delivers high-pressure steam to sealed chambers.
- Autoclaves: Controls thermal cycles for pressure disinfection.
- Laundry Equipment: Feeds steam to ironers and presses.
- Molding Systems: Injects heat into forming mold cavities.
- Steam Atomization Units: Regulates spray heat in humidifying systems.
Compliance and Approvals
- UL Listed
- CSA Certified
- CE Compliant
Installation and Operational Notes
- Always use the correct voltage for the solenoid coil.
- Make sure the system is depressurized before installation.
- Add a strainer or filter close to the inlet.
- Don’t bend or misalign pipes during installation.
- Listen for a click when powering the solenoid.