The Asco 8220G031 Solenoid Valve (8220G31) is a heavy-duty, pilot-operated valve designed for continuous steam and hot water flow in large industrial systems. With enhanced thermal resistance and flow handling, it is built for equipment that demands steady, high-volume delivery. Once opened at higher pressure, the valve will remain open to 3 psi at the inlet.
Technical Specifications
- Valve Type: Pilot Operated, Normally Closed, 2-Way
- Pipe Size: 2″ NPT
- Flow Factor (Cv): 43.0
- Operating Pressure Differential:
- Steam: 5 to 125 psi
- Hot Water: 5 to 150 psi
- Maximum Fluid Temperature:
- Steam: 353°F (178°C)
- Hot Water: 210°F (99°C)
- Body Material: Brass
- Seal Material: EPDM or PTFE
- Voltage Options:
- AC: 24, 120, 240, 480 V
- DC: 6, 12, 24, 120, 240 V
- Watt Rating:
- AC: 10.1 watts
- Coil Insulation Class: H
- Solenoid Enclosure:
- Standard: RedHat II – Watertight, Types 1, 2, 3, 3S, 4, and 4X
- Optional: Explosionproof & Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9
Key Features and Functionality
- High-Temperature Tolerance: Suitable for continuous steam and hot water service.
- Large Flow Capacity: Built to move high volumes with minimal restriction.
- Class H Coil Insulation: Designed for long-term thermal endurance.
- Pilot Operated Performance: Reliable operation under demanding conditions.
- Corrosion-Resistant Construction: Brass body withstands harsh fluid environments.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8220 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Boiler Systems: Controls steam output or hot water return lines.
- Sterilizers and Autoclaves: This facilitates the flow of heat and pressure cycles.
- Process Heating Equipment: Regulates media to temperature-controlled units.
- Industrial Rinse Lines: Delivers high-temperature water to spray systems.
- Steam Distribution Loops: Maintains flow to branch or zone connections.
Compliance and Approvals
- UL Listed
- CSA Certified
- Meets Applicable CE Directives
Installation and Operational Notes
- Confirm the coil voltage matches your power source.
- Depressurize the system before installing or servicing the valve.
- Use a fine strainer upstream to block debris and contaminants.
- Align pipes carefully to avoid straining the valve body.
- Apply power and listen for a click to confirm solenoid actuation.
We ship this product worldwide! Delivery is normally stock.
Request a Quote now or call us at 1-800-755-2883 for expert assistance.