The Asco 8215B080 Solenoid Valve (8215B080CSA) is a direct-acting, normally closed valve designed for shutoff of air and fuel gas in low to moderate pressure systems. With an aluminum body, 0 psi minimum requirement, and dependable Cv 60 flow performance, it’s well-suited for fuel trains and industrial heating applications.

Technical Specifications

  • Valve Type: Direct Acting, Normally Closed, 2-Way
  • Pipe Size: 2″ NPT
  • Flow Factor (Cv): 60
  • Gas Capacity: 3,251,000 BTU/hr
  • Operating Pressure Differential:
    • Air-Fuel Gas: 0 to 25 psi (AC)
  • Maximum Fluid Temperature:
    • AC: 125°F (52°C)
  • Body Material: Aluminum
  • Seal Material: NBR (Nitrile)
  • Voltage Options:
    • AC: 24, 120, 240, 480V
    • DC: 6, 12, 24, 120, 240V
  • Watt Rating:
    • AC: 15.4 watts
  • Coil Insulation Class: F
  • Solenoid Enclosure:
    • Standard: NEMA 4X, IP65 (Watertight, Corrosion-Resistant)
    • Optional: Explosionproof & Watertight (Types 3-9), Raintight (Types 3, 7, 9)

Key Features and Functionality

  • Direct Acting Design: Engages shutoff without pilot pressure.
  • Medium Cv Output: Delivers Cv 60 for air/gas service.
  • Zero Differential Start: Operates from 0 psi inlet pressure.
  • Aluminum Valve Housing: Lightweight for system compatibility.
  • Field-Serviceable Solenoid: Supports quick coil replacement or swap.

Compatible Components and Related Parts

  • ASCO RedHat II Coil Series
  • ASCO Mounting Brackets
  • ASCO Seal Kit for 8215 Series
  • ASCO Explosionproof Solenoid Enclosure

Industry Applications

  • Boiler Gas Shutoff: Used in pre-ignition or pilot gas control.
  • Process Heating Systems: Supplies gas to furnace assemblies.
  • Burner Train Isolation: Provides a secure block on upstream gas.
  • Air Handler Control: Shuts off combustion air in HVAC systems.
  • Paint Booth Heating: Opens fuel path to heating elements.

Compliance and Approvals

  • CSA Certified to C22.2 No. 139
  • UL Rated for Safety Shutoff Valve
  • CE Compliant

Installation and Operational Notes

  • Mount in any position; vertical upright is preferred.
  • Valve operates with zero minimum pressure differential.
  • The manual operator must be fully counterclockwise for the electrical function.
  • Use only clean, dry air or fuel gas with an upstream strainer.
  • Apply pipe compound to male threads only to avoid contamination.

Series Catalog

Asco 8215 Aluminum Body Solenoid Valves

 

We ship this product worldwide! Delivery is normally stock.

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Get A Quote

Fill in the form below, or call us now at 1-800-755-2883

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Full Product Catalog

See our comprehensive product catalog!