Asco 8030G082 Solenoid Valve 8030G82
Asco 8030G082 Solenoid Valve 8030G82

The Asco 8030G082 Solenoid Valve (8030G82) is a normally open, direct-acting solenoid valve designed for low-pressure air and water service. With its full 3/4″ orifice flow path, 5 Cv rating, and zero-pressure actuation, it is well-suited for general-purpose venting, filling, or draining operations in control systems that require default-open functionality.

Technical Specifications

  • Valve Type: Direct Acting, Normally Open, 2-Way
  • Pipe Size: 1/2″ NPT
  • Flow Factor (Cv): 5
  • Operating Pressure Differential:
    • Air/Inert Gas: 0 to 2 psi (AC)
    • Water: 0 to 2 psi (AC)
  • Maximum Fluid Temperature:
    • AC: 180°F (82°C)
  • Body Material: Brass
  • Seal Material: NBR
  • Voltage Options:
    • AC (60Hz): 24, 120, 240, 480V
    • AC (50Hz): 110, 220V
  • Watt Rating:
    • AC: 10.1 watts
  • Coil Insulation Class: F
  • Solenoid Enclosure:
    • Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X
    • Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9

Key Features and Functionality

  • Normally Open Flow: Allows fluid to pass when de-energized.
  • Zero Pressure Required: Functions without differential inlet pressure.
  • Large Cv Capacity: Enables faster fill or drain rates.
  • Moderate Heat Rating: Tolerates fluid up to 180°F temperature.
  • Compact Brass Housing: Fits easily into general-use piping layouts.

Compatible Components and Related Parts

  • ASCO RedHat II Coil Series
  • ASCO Mounting Brackets
  • ASCO Seal Kit for 8030 Series
  • ASCO Explosionproof Solenoid Enclosure

Industry Applications

  • Tank Fill Systems: Opens by default to let fluid enter.
  • Vent Line Control: Passively relieves pressure from process lines.
  • Purge Valve Circuits: Allows air or fluid to flow out.
  • General Fluid Distribution: Maintains open flow unless energized.
  • Standby Bypass Flow: Keeps alternate path open for process support.

Compliance and Approvals

  • CSA Certified
  • FM Approved
  • CE Compliant

Installation and Operational Notes

  • Shut off the power and depressurize before servicing.
  • Clean the valve periodically, depending on service conditions.
  • Use a strainer or filter close to the valve.
  • Mount in any position; vertical preferred.
  • No minimum pressure differential is required.

Series Catalog

Asco 8030 Low-Pressure Solenoid Valves

 

We ship this product worldwide! Delivery is normally stock.

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

Get A Quote

Fill in the form below, or call us now at 1-800-755-2883

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Full Product Catalog

See our comprehensive product catalog!