The Asco 8015B213 Solenoid Valve is a corrosion-resistant solenoid valve configured for stable shutoff in heated, chemically aggressive process lines. Sized for steady throughput in small-to-mid utility loops, it features a latched-open design with an electrically triggered trip. Ideal for systems that demand deliberate restart procedures and robust material compatibility.
Technical Specifications
- Valve Type: Manual Reset, Special Service Pilot, Latched Open
- Pipe Size: 1″ NPT
- Flow Factor (Cv): 11.2
- Operating Pressure Differential
- Air/Inert Gas, Corrosives: 5 to 125 psi (AC), 5 to 125 psi (DC)
- Maximum Fluid Temperature
- AC: 350°F (177°C)
- DC: 350°F (177°C)
- Body Material: Stainless Steel
- Seal Material: PTFE Disc, FPM Seals
- Voltage Options
- AC (60Hz): 24, 120, 240, 480V
- AC (50Hz): 110, 220V
- DC: 6, 12, 24, 120, 240V
- Watt Rating
- AC: 20 watts
- DC: 36.2 watts
- Coil Insulation Class: F (AC), H (DC)
- Solenoid Enclosure
- Standard: Type 1 General Purpose Junction Box.
- Optional: Explosionproof and Watertight, Types 3, 7(C and D), and 9
Key Features and Functionality
- Corrosive Service Material: Stainless steel and PTFE for chemical use.
- Electrically Tripped Shutdown: The valve closes when the coil is energized.
- Latched Open Safety: Remains open until shutdown is triggered.
- Moderate Flow Design: Supports steady throughput in small process loops.
- Manual Reset Mechanism: Requires user action to restore operation.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8015 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Chemical Injection Units: Controls aggressive fluid metering lines.
- Corrosive Washdown Systems: Manual shutoff in hazardous rinse processes.
- Environmental Sampling Skids: Valve protection in pH-adjusted circuits.
- Biotech Reactors: Shutdown control in CIP and chemical dosing loops.
- Neutralization Chambers: Flow isolation for base/acid blend tanks.
Compliance and Approvals
- CSA Certified
- For corrosive media use
- Optional explosionproof enclosure available
Installation and Operational Notes
- Mount the solenoid coil vertically for safe operation.
- Ensure clear access to the manual reset lever.
- Energize the trip signal for a minimum of 0.3 seconds.
- Reset required only after the solenoid is de-energized.
- Use only with approved corrosive or inert fluids.
- Verify that operating conditions match pressure and temperature ratings.
Series Catalog
Asco 8015/8025 Manual Reset Valves
We ship this product worldwide! Delivery is normally stock.
Request a Quote now or call us at 1-800-755-2883 for expert assistance.