The Asco 8015B211 Solenoid Valve is engineered for corrosive media shutoff in high-pressure, high-temperature systems. Built with a stainless steel body and PTFE disc, it resists aggressive chemicals and fluid breakdown. The electrically tripped, latched-open configuration ensures safe shutdown control in harsh process environments where reliability and manual reset are critical.
Technical Specifications
- Valve Type: Manual Reset, Special Service Pilot, Latched Open
- Pipe Size: 1/2″ NPT
- Flow Factor (Cv): 3.2
- Operating Pressure Differential
- Air/Inert Gas, Corrosives: 5 to 250 psi (AC), 5 to 250 psi (DC)
- Maximum Fluid Temperature
- AC: 350°F (177°C)
- DC: 350°F (177°C)
- Body Material: Stainless Steel
- Seal Material: PTFE Disc, FPM Seals
- Voltage Options
- AC (60Hz): 24, 120, 240, 480V
- AC (50Hz): 110, 220V
- DC: 6, 12, 24, 120, 240V
- Watt Rating
- AC: 20 watts
- DC: 36.2 watts
- Coil Insulation Class: F (AC), H (DC)
- Solenoid Enclosure
- Standard: Type 1 General Purpose Junction Box.
- Optional: Explosionproof and Watertight, Types 3, 7(C and D), and 9
Key Features and Functionality
- Corrosion-Resistant Build: Stainless steel body and PTFE disc assembly.
- Electrically Tripped Shutdown: Closes when coil receives electrical signal.
- Latched Open Operation: The flow remains open until a manual reset follows the trip.
- High-Pressure Compatibility: Designed for pressurized process environments.
- Manual Reset Safety: Prevents automatic restart without user intervention.
Compatible Components and Related Parts
- ASCO RedHat II Coil Series
- ASCO Mounting Brackets
- ASCO Seal Kit for 8015 Series
- ASCO Explosionproof Solenoid Enclosure
Industry Applications
- Chemical Feed Systems: Controlled isolation in aggressive fluid lines.
- Acid Neutralization Skids: Secure shutoff in corrosion-prone conditions.
- Pharmaceutical Steam Loops: Chemical-grade control with reset protection.
- Semiconductor Processing: Trip valves for specialty chemical services.
- Water Purification Units: Safe closure in high-purity corrosive circuits.
Compliance and Approvals
- CSA Certified
- Suitable for corrosive service
- Optional explosionproof coil housing available
Installation and Operational Notes
- Install in an upright orientation with the coil facing upward.
- Reset required after energized trip cycle completes.
- Compatible with corrosive fluid streams only.
- A trip signal must last at least 0.3 seconds.
- Always match system pressure/temperature to product ratings.
Series Catalog