ABB low voltage AC drives provide a versatile portfolio for precise motor control and significant energy savings across micro, machinery, and general purpose applications. Spanning 0.18 to 5600 kW, the range includes the ACS150 (micro), ACS355 (machinery), ACS310 (general purpose), ACS480 (general purpose), and ACS580 (general purpose), ideal for pumps, fans, conveyors, material handling, and more. Featuring built-in energy efficiency calculators, Safe Torque Off (SIL3/PL e), and compliance with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level for ACS480, ACS580), these drives offer easy installation, commissioning, and operation. With compact designs, intuitive interfaces, and connectivity options like Modbus RTU, ABB drives maximize uptime and performance in diverse industrial settings.

ABB Low Voltage AC Drives Technical Data

Input
  • Input configuration: 1-phase (200–240 V) for ACS150, ACS355, ACS310; 3-phase (200–240 V, 380–480 V) for ACS150, ACS355, ACS310, ACS480, ACS580
  • Input voltage variation: Suitable for standard 1-phase and 3-phase supplies
Output
  • Output power:
    • ACS150: 0.37 to 2.2 kW (1-phase, 200–240 V), 0.37 to 4 kW (3-phase, 200–240 V, 380–480 V)
    • ACS355: 0.37 to 11 kW (1-phase, 200–240 V), 0.37 to 22 kW (3-phase, 200–240 V, 380–480 V)
    • ACS310: 0.37 to 11 kW (1-phase, 200–240 V), 0.37 to 22 kW (3-phase, 200–240 V, 380–480 V)
    • ACS480: 0.75 to 22 kW (3-phase, 380–480 V)
    • ACS580: 0.75 to 75 kW (3-phase, 200–240 V), 0.75 to 500 kW (3-phase, 380–480 V)
  • Output voltage: 0 to Un (200–240 V or 380–480 V, depending on drive)
  • Output frequency: 0 to 599 Hz
  • Motor type: Induction motors, compatible with high-efficiency motors (e.g., IE4 for ACS480, ACS580)
Mechanical
  • Enclosure: IP20 (standard for ACS480, ACS580), IP20/IP66/IP67 options for ACS150, ACS355, ACS310
  • Dimensions and weights: Varies by frame size, specified in ratings tables for ACS150, ACS355, ACS480, ACS580
Environmental
  • Altitude: Up to 1000 m without derating (up to 4000 m with derating)
  • Ambient air temperature: 0 to 50°C (derating above 40°C)
  • Cooling type: Air-cooled
Standards
  • Standards: CE marked, complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level for ACS480, ACS580), UL certified, fulfills Machinery Directive 2006/42/EC
Ratings, Types and Voltages: ACS480, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Light-Duty Use Heavy-Duty Use ABB Ordering Code (IP20) Type Code Frame Size
P_ld (kW) I_ld (A) P_hd (kW) I_hd (A)
0.75 2.5 0.55 1.8 3AXD50000047765 ACS480-04-02A7-4 R1
1.1 3.1 0.75 2.6 3AXD50000047766 ACS480-04-03A4-4 R1
1.5 3.8 1.1 3.3 3AXD50000047767 ACS480-04-04A1-4 R1
2.2 5.3 1.5 4 3AXD50000047768 ACS480-04-05A7-4 R1
3 6.8 2.2 5.6 3AXD50000047769 ACS480-04-07A3-4 R1
4 8.9 3 7.2 3AXD50000047770 ACS480-04-09A5-4 R1
5.5 12 4 9.4 3AXD50000047791 ACS480-04-12A7-4 R2
7.5 16.2 5.5 12.6 3AXD50000047792 ACS480-04-018A-4 R3
11 23.8 7.5 17 3AXD50000047793 ACS480-04-026A-4 R3
15 30.5 11 25 3AXD50000199068 ACS480-04-033A-4 R4
18.5 36 15 32 3AXD50000199075 ACS480-04-039A-4 R4
22 42.8 18.5 38 3AXD50000199082 ACS480-04-046A-4 R4
22 48 22 45 3AXD50000199099 ACS480-04-050A-4 R4
Light-duty use: P_ld = Typical motor power in light-duty use; I_ld = Continuous current allowing 110% I_ld for 1 min/10 min at 50°C.
Heavy-duty use: P_hd = Typical motor power in heavy-duty use; I_hd = Continuous current allowing 150% I_hd for 1 min/10 min at 50°C.
Indicative information: Ratings apply at 50°C ambient temperature and up to 1000 m above sea level. For higher altitudes (max. 4000 m) or temperatures, deratings apply. Integrated C2 EMC filter, Safe Torque Off (SIL3/PL e), and brake chopper included. Complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level).
Ratings, Types and Voltages: ACS580, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Light-Duty Use Heavy-Duty Use ABB Ordering Code (IP21) Type Code Frame Size
P_ld (kW) I_ld (A) P_hd (kW) I_hd (A)
0.75 2.5 0.75 2.5 3AXD50000003837 ACS580-01-02A7-4 R1
1.1 3.1 1.1 3.1 3AXD50000003838 ACS580-01-03A4-4 R1
1.5 3.8 1.5 3.8 3AXD50000003839 ACS580-01-04A1-4 R1
2.2 5.3 2.2 5.3 3AXD50000003840 ACS580-01-05A7-4 R1
3 6.8 3 6.8 3AXD50000003841 ACS580-01-07A3-4 R1
4 8.9 4 8.9 3AXD50000003842 ACS580-01-09A5-4 R1
5.5 12 5.5 12 3AXD50000003853 ACS580-01-12A7-4 R1
7.5 16.2 7.5 16.2 3AXD50000003855 ACS580-01-018A-4 R2
11 23.8 11 23.8 3AXD50000003860 ACS580-01-026A-4 R2
15 30.4 15 30.4 3AXD50000003861 ACS580-01-032A-4 R3
18.5 36.1 18.5 36.1 3AXD50000003862 ACS580-01-039A-4 R3
22 42.8 22 42.8 3AXD50000003863 ACS580-01-046A-4 R3
30 58 30 58 3AUA0000080469 ACS580-01-062A-4 R4
37 64.4 37 64.4 3AUA0000080470 ACS580-01-073A-4 R4
45 83 45 83 3AUA0000080471 ACS580-01-088A-4 R5
55 100 55 100 3AUA0000080472 ACS580-01-106A-4 R5
75 138 75 138 3AUA0000080504 ACS580-01-145A-4 R6
90 151 90 151 3AUA0000080505 ACS580-01-169A-4 R6
110 186 110 186 3AUA0000080506 ACS580-01-206A-4 R7
132 234 132 234 3AUA0000080507 ACS580-01-246A-4 R7
160 278 160 278 3AUA0000080508 ACS580-01-293A-4 R8
200 345 200 345 3AUA0000080509 ACS580-01-363A-4 R8
250 400 250 400 3AUA0000080510 ACS580-01-430A-4 R9
Light-duty use: P_ld = Typical motor power in light-duty use; I_ld = Continuous current allowing 110% I_ld for 1 min/10 min at 50°C.
Heavy-duty use: P_hd = Typical motor power in heavy-duty use; I_hd = Continuous current allowing 150% I_hd for 1 min/10 min at 50°C.
Indicative information: Ratings apply at 50°C ambient temperature and up to 1000 m above sea level. For higher altitudes (max. 4000 m) or temperatures, deratings apply. Integrated C2 EMC filter, Safe Torque Off (SIL3/PL e), and brake chopper included. Complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level).
Ratings, Types and Voltages: ACS580, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Light-Duty Use Heavy-Duty Use ABB Ordering Code (IP55) Type Code Frame Size
P_ld (kW) I_ld (A) P_hd (kW) I_hd (A)
0.75 2.5 0.55 1.8 3AXD50000038965 ACS580-01-02A7-4+B056 R1
1.1 3.1 0.75 2.6 3AXD50000038966 ACS580-01-03A4-4+B056 R1
1.5 3.8 1.1 3.3 3AXD50000038967 ACS580-01-04A1-4+B056 R1
2.2 5.3 1.5 4 3AXD50000038968 ACS580-01-05A7-4+B056 R1
3 6.8 2.2 5.6 3AXD50000038969 ACS580-01-07A3-4+B056 R1
4 8.9 3 7.2 3AXD50000038970 ACS580-01-09A5-4+B056 R1
5.5 12 4 9.4 3AXD50000038976 ACS580-01-12A7-4+B056 R1
7.5 16.2 5.5 12.6 3AXD50000038977 ACS580-01-018A-4+B056 R2
11 23.8 7.5 17 3AXD50000038978 ACS580-01-026A-4+B056 R2
15 30.4 11 24.6 3AXD50000038979 ACS580-01-032A-4+B056 R3
18.5 36.1 15 31.6 3AXD50000038980 ACS580-01-039A-4+B056 R3
22 42.8 18.5 37.7 3AXD50000038981 ACS580-01-046A-4+B056 R3
30 58 22 44.6 3AUA0000083573 ACS580-01-062A-4+B056 R4
37 64.4 30 61 3AUA0000083574 ACS580-01-073A-4+B056 R4
45 83 37 72 3AUA0000083575 ACS580-01-088A-4+B056 R5
55 100 45 87 3AUA0000083576 ACS580-01-106A-4+B056 R5
75 138 55 105 3AUA0000083578 ACS580-01-145A-4+B056 R6
90 151 75 145 3AUA0000083580 ACS580-01-169A-4+B056 R6
110 186 90 169 3AUA0000083581 ACS580-01-206A-4+B056 R7
132 234 110 206 3AUA0000083582 ACS580-01-246A-4+B056 R7
160 278 132 246 3AUA0000083583 ACS580-01-293A-4+B056 R8
200 345 160 293 3AUA0000083584 ACS580-01-363A-4+B056 R8
250 400 200 363 3AUA0000083585 ACS580-01-430A-4+B056 R9
Light-duty use: P_ld = Typical motor power in light-duty use; I_ld = Continuous current allowing 110% I_ld for 1 min/10 min at 50°C.
Heavy-duty use: P_hd = Typical motor power in heavy-duty use; I_hd = Continuous current allowing 150% I_hd for 1 min/10 min at 50°C.
Indicative information: Ratings apply at 50°C ambient temperature and up to 1000 m above sea level. For higher altitudes (max. 4000 m) or temperatures, deratings apply. Integrated C2 EMC filter, Safe Torque Off (SIL3/PL e), and brake chopper included. Complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level).
For more technical information, see ACS580 catalog (3AUA0000145061 EN) or ABB drives product guide (3AFE68401771 EN).
Ratings, Types and Voltages: ACS580, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Light-Duty Use Heavy-Duty Use ABB Ordering Code (IP00) Type Code Frame Size
P_ld (kW) I_ld (A) P_hd (kW) I_hd (A)
250 485 200 361 3AUA0000184475 ACS580-04-505A-4 R10
315 575 250 429 3AUA0000184601 ACS580-04-585A-4 R10
355 634 250 477 3AUA0000184651 ACS580-04-650A-4 R10
400 715 315 566 3AUA0000184652 ACS580-04-725A-4 R11
450 810 355 625 3AUA0000184663 ACS580-04-820A-4 R11
500 865 400 725 3AUA0000184676 ACS580-04-880A-4 R11
Light-duty use: P_ld = Typical motor power in light-duty use; I_ld = Continuous current allowing 110% I_ld for 1 min/10 min at 50°C.
Heavy-duty use: P_hd = Typical motor power in heavy-duty use; I_hd = Continuous current allowing 150% I_hd for 1 min/10 min at 50°C.
Indicative information: Ratings apply at 50°C ambient temperature and up to 1000 m above sea level. For higher altitudes (max. 4000 m) or temperatures, deratings apply. Integrated C2 EMC filter, Safe Torque Off (SIL3/PL e), and brake chopper included. Complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level).
Ratings, Types and Voltages: ACS580, 3-phase, Drive input voltage 208–240 V, Motor nominal voltage 208–240 V
Light-Duty Use Heavy-Duty Use ABB Ordering Code (IP00) Type Code Frame Size
P_ld (kW) I_ld (A) P_hd (kW) I_hd (A)
0.75 4.6 0.55 3.5 3AXD50000017396 ACS580-01-04A7-2 R1
1.1 6 0.75 4.6 3AXD50000017397 ACS580-01-06A7-2 R1
1.5 8 1.1 6 3AXD50000017398 ACS580-01-07A6-2 R1
2.2 11 1.5 8 3AXD50000017399 ACS580-01-011A-2 R1
3 12.9 2.2 11 3AXD50000017400 ACS580-01-013A-2 R1
4 17.5 3 12.9 3AXD50000017401 ACS580-01-018A-2 R1
5.5 24.6 4 17.5 3AXD50000017402 ACS580-01-025A-2 R2
7.5 30.8 5.5 24.6 3AXD50000017403 ACS580-01-032A-2 R2
11 46.2 7.5 30.8 3AXD50000017404 ACS580-01-047A-2 R3
15 59.4 11 46.2 3AXD50000017405 ACS580-01-060A-2 R3
18.5 74.8 15 59.4 3AXD50000017406 ACS580-01-075A-2 R3
22 88 18.5 74.8 3AXD50000017407 ACS580-01-088A-2 R4
30 114 22 88 3AXD50000017408 ACS580-01-114A-2 R5
37 143 30 114 3AXD50000017409 ACS580-01-143A-2 R6
45 169 37 143 3AXD50000017410 ACS580-01-169A-2 R6
55 211 45 169 3AXD50000017411 ACS580-01-211A-2 R7
Light-duty use: P_ld = Typical motor power in light-duty use; I_ld = Continuous current allowing 110% I_ld for 1 min/10 min at 50°C.
Heavy-duty use: P_hd = Typical motor power in heavy-duty use; I_hd = Continuous current allowing 150% I_hd for 1 min/10 min at 50°C.
Indicative information: Ratings apply at 50°C ambient temperature and up to 1000 m above sea level. For higher altitudes (max. 4000 m) or temperatures, deratings apply. Integrated C2 EMC filter, Safe Torque Off (SIL3/PL e), and brake chopper included. Complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level).
For more technical information, see ACS580 catalog (3AUA0000145061 EN) or ABB drives product guide (3AFE68401771 EN).
Ratings, Types and Voltages: ACS580, 3-phase, Drive input voltage 208–240 V, Motor nominal voltage 208–240 V
Light-Duty Use Heavy-Duty Use ABB Ordering Code (IP55) Type Code Frame Size
P_ld (kW) I_ld (A) P_hd (kW) I_hd (A)
0.75 4.6 0.55 3.5 3AXD50000017412 ACS580-01-04A7-2+B056 R1
1.1 6 0.75 4.6 3AXD50000017413 ACS580-01-06A7-2+B056 R1
1.5 8 1.1 6 3AXD50000017414 ACS580-01-07A6-2+B056 R1
2.2 11 1.5 8 3AXD50000017415 ACS580-01-011A-2+B056 R1
3 12.9 2.2 11 3AXD50000017416 ACS580-01-013A-2+B056 R1
4 17.5 3 12.9 3AXD50000017417 ACS580-01-018A-2+B056 R1
5.5 24.6 4 17.5 3AXD50000017418 ACS580-01-025A-2+B056 R2
7.5 30.8 5.5 24.6 3AXD50000017419 ACS580-01-032A-2+B056 R2
11 46.2 7.5 30.8 3AXD50000017420 ACS580-01-047A-2+B056 R3
15 59.4 11 46.2 3AXD50000017421 ACS580-01-060A-2+B056 R3
18.5 74.8 15 59.4 3AXD50000017422 ACS580-01-075A-2+B056 R3
22 88 18.5 74.8 3AXD50000017423 ACS580-01-088A-2+B056 R4
30 114 22 88 3AXD50000017424 ACS580-01-114A-2+B056 R5
37 143 30 114 3AXD50000017425 ACS580-01-143A-2+B056 R6
45 169 37 143 3AXD50000017426 ACS580-01-169A-2+B056 R6
55 211 45 169 3AXD50000017427 ACS580-01-211A-2+B056 R7
Light-duty use: P_ld = Typical motor power in light-duty use; I_ld = Continuous current allowing 110% I_ld for 1 min/10 min at 50°C.
Heavy-duty use: P_hd = Typical motor power in heavy-duty use; I_hd = Continuous current allowing 150% I_hd for 1 min/10 min at 50°C.
Indicative information: Ratings apply at 50°C ambient temperature and up to 1000 m above sea level. For higher altitudes (max. 4000 m) or temperatures, deratings apply. Integrated C2 EMC filter, Safe Torque Off (SIL3/PL e), and brake chopper included. Complies with EU Ecodesign Regulation (EU) 2019/1781 (IE2 efficiency level).
For more technical information, see ACS580 catalog (3AUA0000145061 EN) or ABB drives product guide (3AFE68401771 EN).
Ratings, Types and Voltages: ACS150, 1-phase, Drive input voltage 200–240 V, Motor nominal voltage 200–240 V
Rated Values* ABB Ordering Code (IP20) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 2.4 68581940 ACS150-01E-02A4-2 R0
0.75 4.7 68581966 ACS150-01E-04A7-2 R1
1.1 6.7 68581974 ACS150-01E-06A7-2 R1
1.5 7.5 68581982 ACS150-01E-07A5-2 R2
2.2 9.8 68581991 ACS150-01E-09A8-2 R2
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
Ratings, Types and Voltages: ACS150, 3-phase, Drive input voltage 200–240 V, Motor nominal voltage 200–240 V
Rated Values* ABB Ordering Code (IP20) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 2.4 68582008 ACS150-03E-02A4-2 R0
0.55 3.5 68582016 ACS150-03E-03A5-2 R0
0.75 4.7 68582024 ACS150-03E-04A7-2 R1
1.1 6.7 68582032 ACS150-03E-06A7-2 R1
1.5 7.5 68582041 ACS150-03E-07A5-2 R1
2.2 9.8 68582059 ACS150-03E-09A8-2 R2
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
Ratings, Types and Voltages: ACS150, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Rated Values* ABB Ordering Code (IP20) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 1.2 68581737 ACS150-03E-01A2-4 R0
0.55 1.9 68581745 ACS150-03E-01A9-4 R0
0.75 2.4 68581753 ACS150-03E-02A4-4 R1
1.1 3.3 68581761 ACS150-03E-03A3-4 R1
1.5 4.1 68581788 ACS150-03E-04A1-4 R1
2.2 5.6 68581796 ACS150-03E-05A6-4 R1
3 7.3 68581800 ACS150-03E-07A3-4 R1
4 8.8 68581818 ACS150-03E-08A8-4 R1
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
Ratings, Types and Voltages: ACS355, 1-phase, Drive input voltage 200–240 V, Motor nominal voltage 200–240 V
Rated Values* ABB Ordering Code (IP66) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 2.4 3AUA0000058167 ACS355-01E-02A4-2 R0
0.75 4.7 3AUA0000058168 ACS355-01E-04A7-2 R1
1.1 6.7 3AUA0000058169 ACS355-01E-06A7-2 R1
1.5 7.5 3AUA0000058170 ACS355-01E-07A5-2 R2
2.2 9.8 3AUA0000058171 ACS355-01E-09A8-2 R2
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
Ratings, Types and Voltages: ACS355, 3-phase, Drive input voltage 200–240 V, Motor nominal voltage 200–240 V
Rated Values* ABB Ordering Code (IP66) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 2.4 3AUA0000058172 ACS355-03E-02A4-2 R0
0.55 3.5 3AUA0000058173 ACS355-03E-03A5-2 R0
0.75 4.7 3AUA0000058174 ACS355-03E-04A7-2 R1
1.1 6.7 3AUA0000058175 ACS355-03E-06A7-2 R1
1.5 7.5 3AUA0000058176 ACS355-03E-07A5-2 R1
2.2 9.8 3AUA0000058177 ACS355-03E-09A8-2 R2
3 13.3 3AUA0000058178 ACS355-03E-13A3-2 R2
4 17.6 3AUA0000058179 ACS355-03E-17A6-2 R2
5.5 24.4 3AUA0000058180 ACS355-03E-24A4-2 R3
7.5 31.0 3AUA0000058181 ACS355-03E-31A0-2 R4
11 46.2 3AUA0000058182 ACS355-03E-46A2-2 R4
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
Ratings, Types and Voltages: ACS355, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Rated Values* ABB Ordering Code (IP66) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 1.2 3AUA0000058183 ACS355-03E-01A2-4 R0
0.55 1.9 3AUA0000058184 ACS355-03E-01A9-4 R0
0.75 2.4 3AUA0000058185 ACS355-03E-02A4-4 R1
1.1 3.3 3AUA0000058186 ACS355-03E-03A3-4 R1
1.5 4.1 3AUA0000058187 ACS355-03E-04A1-4 R1
2.2 5.6 3AUA0000058188 ACS355-03E-05A6-4 R1
3 7.3 3AUA0000058189 ACS355-03E-07A3-4 R1
4 8.8 3AUA0000058190 ACS355-03E-08A8-4 R1
5.5 12.5 3AUA0000058191 ACS355-03E-12A5-4 R3
7.5 15.6 3AUA0000058192 ACS355-03E-15A6-4 R3
11 23.1 3AUA0000058193 ACS355-03E-23A1-4 R3
15 31.0 3AUA0000058194 ACS355-03E-31A0-4 R4
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
Ratings, Types and Voltages: ACS355, 2-phase, Drive input voltage 200–240 V, Motor nominal voltage 200–240 V
Rated Values* ABB Ordering Code (IP66/IP67) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 2.4 3AUA0000058148 ACS355-03X-02A4-2 + B063 R1
0.55 3.5 3AUA0000058149 ACS355-03X-03A5-2 + B063 R1
0.75 4.7 3AUA0000058150 ACS355-03X-04A7-2 + B063 R1
1.1 6.7 3AUA0000058151 ACS355-03X-06A7-2 + B063 R1
1.5 7.5 3AUA0000058152 ACS355-03X-07A5-2 + B063 R1
2.2 9.8 3AUA0000058153 ACS355-03X-09A8-2 + B063 R3
3 13.3 3AUA0000058154 ACS355-03X-13A3-2 + B063 R3
4 17.6 3AUA0000058155 ACS355-03X-17A6-2 + B063 R3
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
X within the type code stands for E or U.
Ratings, Types and Voltages: ACS355, 3-phase, Drive input voltage 380–480 V, Motor nominal voltage 380–480 V
Rated Values* ABB Ordering Code (IP66/IP67) Type Code Frame Size
P_n (kW) I_2N (A)
0.37 1.2 3AUA0000058156 ACS355-03X-01A2-4 + B063 R1
0.55 1.9 3AUA0000058157 ACS355-03X-01A9-4 + B063 R1
0.75 2.4 3AUA0000058158 ACS355-03X-02A4-4 + B063 R1
1.1 3.3 3AUA0000058159 ACS355-03X-03A3-4 + B063 R1
1.5 4.1 3AUA0000058160 ACS355-03X-04A1-4 + B063 R1
2.2 5.6 3AUA0000058161 ACS355-03X-05A6-4 + B063 R1
3 7.3 3AUA0000058162 ACS355-03X-07A3-4 + B063 R1
4 8.8 3AUA0000058163 ACS355-03X-08A8-4 + B063 R1
5.5 12.5 3AUA0000058164 ACS355-03X-12A5-4 + B063 R3
7.5 15.6 3AUA0000058165 ACS355-03X-15A6-4 + B063 R3
* The rated power and current values are valid for both pump and fan applications and heavy load applications. Examples of heavy load applications include most extruders and compressors.
X within the type code stands for E or U.

Get A Quote

Fill in the form below, or call us now at 1-800-755-2883

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

Full Product Catalog

See our comprehensive product catalog!